Measurement on ECHOSOFT
6.1 Evoked potential modul (ABR, ECochG et VEMP)
6.1
Evoked potential modul (ABR, ECochG et VEMP)
Erreur ! Source du renvoi introuvable.
(VEMP) to obtain the necessary
instructions about the needed equipment and the setup.
6.1.1
Test window
There are three different modes to adjust the characteristics of performing an ABR measurement:
•
A “
manual
” mode where everything is set for each new curve (see
Erreur ! Source du renvoi introuvable.
).
•
An “
automatic
” mode where you choose at the beginning all the measurements that will have to be made (see
Er-
reur ! Source du renvoi introuvable.
).
•
A “
script
” mode where you create predefined protocols that can be saved and reloaded (see
).
For ABR, there is also a “
screening
” mode (see
Erreur ! Source du renvoi introuvable.
)
These modes are accessible through the tabs at the top left of the window (item 1). Whatever the chosen mode of
measurement, the presentation of the curves remains the same. Only the vertical left frame (item 1) changes. The curves
are shown as follows:
1.
Different settings specific to the measurement mode selected (the manual mode on the picture above).
2.
Select the display mode (Either all curves are on the same graph or on a left and right graph - see
) Enables the display of real-time measurement (see
Erreur ! Source du renvoi introu-
vable.
).
3.
Display impedances for each electrode. Select the audio output (jack or DIN) and identification of the headset
connected on it. Information on the progress of the measurement (see
for more details)
4.
Muscular contraction strength (only for
cVEMP
) (see
Erreur ! Source du renvoi introuvable.
):
5.
Switch between curves and latency graph (for
ABR
and
ECochG
6.
Realtime display (see
Erreur ! Source du renvoi introuvable.
).
7.
Display the current recorded curve as well as all curves previously recorded (For more details about curves reading
and manipulation, see subsection
Erreur ! Source du renvoi introuvable.
).
To optimize the life length of the battery, the screen will turn off after two minutes when you use the
ECHO-
SOFT
. To turn it back on, click on the “On/Off” button