5.3.29 99-* Devel support
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
99-0* DSP Debug
99-00 DAC 1 selection
ExpressionLimit
1 set-up
TRUE
0
Uint8
99-01 DAC 2 selection
ExpressionLimit
1 set-up
TRUE
0
Uint8
99-02 DAC 3 selection
ExpressionLimit
1 set-up
TRUE
0
Uint8
99-03 DAC 4 selection
ExpressionLimit
1 set-up
TRUE
0
Uint8
99-04 DAC 1 scale
0 N/A
1 set-up
TRUE
0
Uint8
99-05 DAC 2 scale
0 N/A
1 set-up
TRUE
0
Uint8
99-06 DAC 3 scale
0 N/A
1 set-up
TRUE
0
Uint8
99-07 DAC 4 scale
0 N/A
1 set-up
TRUE
0
Uint8
99-08 Test param 1
0 N/A
1 set-up
TRUE
0
Int32
99-09 Test param 2
0 N/A
1 set-up
TRUE
0
Int32
99-10 DAC Option Slot
[0] None
1 set-up
TRUE
-
Uint8
99-1* Hardware Control
99-11 RFI 2
[1] On
1 set-up
FALSE
-
Uint8
99-12 Fan
[2] Auto
1 set-up
TRUE
-
Uint8
99-1* Software Readouts
99-13 Idle time
0 %
All set-ups
TRUE
-1
Uint16
99-14 Paramdb requests in queue
0 N/A
All set-ups
TRUE
0
Uint16
99-15 Secondary Timer at Inverter Fault
0 N/A
All set-ups
TRUE
0
Uint8
99-16 No of Current Sensors
3 N/A
All set-ups
TRUE
0
Uint8
99-17 tCon1 time
0 us
All set-ups
TRUE
-6
Uint16
99-18 tCon2 time
0 us
All set-ups
TRUE
-6
Uint16
99-19 Time Optimize Measure
0 us
All set-ups
TRUE
-7
Uint16
99-20 Fan Ctrl deltaT
0 N/A
All set-ups
x
TRUE
-4
Int32
99-21 Fan Ctrl Tmean
0 N/A
All set-ups
x
TRUE
-4
Int32
99-22 Fan Ctrl NTC Cmd
0 N/A
All set-ups
x
TRUE
-4
Int32
99-23 Fan Ctrl i-term
0 N/A
All set-ups
x
TRUE
-4
Int32
99-24 Rectifier Current
0 A
All set-ups
x
TRUE
-2
Int32
99-4* Software Control
99-40 StartupWizardState
0 N/A
1 set-up
TRUE
0
Uint16
99-5* PC Debug
99-50 PC Debug Selection
0 N/A
All set-ups
x
TRUE
0
Uint16
99-51 PC Debug Argument
0 N/A
All set-ups
x
TRUE
0
Uint16
99-52 PC Debug 0
0 N/A
All set-ups
x
TRUE
0
VisStr[
12]
99-53 PC Debug 1
0 N/A
All set-ups
x
TRUE
0
VisStr[
12]
99-54 PC Debug 2
0 N/A
All set-ups
x
TRUE
0
VisStr[
12]
99-55 PC Debug Array
0 N/A
All set-ups
x
TRUE
0
VisStr[
12]
99-6* Fan Power Card Dev
99-60 FPC Debug Selection
0 N/A
All set-ups
x
TRUE
0
Uint16
99-61 FPC Debug 0
0 N/A
All set-ups
x
TRUE
0
VisStr[
20]
99-62 FPC Debug 1
0 N/A
All set-ups
x
TRUE
0
VisStr[
20]
99-63 FPC Debug 2
0 N/A
All set-ups
x
TRUE
0
VisStr[
20]
99-64 FPC Debug 3
0 N/A
All set-ups
x
TRUE
0
VisStr[
20]
99-65 FPC Debug 4
0 N/A
All set-ups
x
TRUE
0
VisStr[
20]
99-66 FPC Backdoor
0 N/A
All set-ups
x
TRUE
0
Uint32
99-8* RTDC
99-80 tCon1 Selection
65535 N/A
2 set-ups
FALSE
0
Uint16
99-81 tCon2 Selection
65535 N/A
2 set-ups
FALSE
0
Uint16
99-82 Trig Compare Selection
65535 N/A
2 set-ups
FALSE
0
Uint16
99-83 Trig Compare Operator
[2] >
2 set-ups
FALSE
-
Uint8
99-84 Trig Compare Operand
0 N/A
2 set-ups
FALSE
0
Int32
99-85 Trig Start
0 ms
2 set-ups
FALSE
-3
Uint32
99-86 Pre-trigger
0 ms
2 set-ups
FALSE
-3
Uint16
99-9* Internal Values
99-90 Options present
ExpressionLimit
1 set-up
FALSE
0
Uint8
99-91 Motor Power Internal
ExpressionLimit
All set-ups
FALSE
1
Uint32
99-92 Motor Voltage Internal
ExpressionLimit
All set-ups
FALSE
0
Uint16
99-93 Motor Frequency Internal
ExpressionLimit
All set-ups
TRUE
-1
Uint16
99-94 Imbalance derate [%]
0 %
All set-ups
FALSE
-2
N2
99-95 Temperature derate [%]
0 %
All set-ups
FALSE
-2
N2
99-96 Overload derate [%]
0 %
All set-ups
FALSE
-2
N2
Table 5.16
Parameter Lists
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
323
5
5