13-40 Logic Rule Boolean 1
Option:
Function:
ETR
or
[21] Advanced ETR
. If
warning
165, ATEX ETR freq.lim.warning
is active,
the output is 1.
[94]
RS Flipflop 0
See
parameter group 13-1*
Comparators
.
[95]
RS Flipflop 1
See
parameter group 13-1*
Comparators
.
[96]
RS Flipflop 2
See
parameter group 13-1*
Comparators
.
[97]
RS Flipflop 3
See
parameter group 13-1*
Comparators
.
[98]
RS Flipflop 4
See
parameter group 13-1*
Comparators
.
[99]
RS Flipflop 5
See
parameter group 13-1*
Comparators
.
[100] RS Flipflop 6
See
parameter group 13-1*
Comparators
.
[101] RS Flipflop 7
See
parameter group 13-1*
Comparators
.
[102] Relay 1
[103] Relay 2
[104] Relay 3
X47/VLT
®
Extended Relay Card MCB
113.
[105] Relay 4
X47/VLT
®
Extended Relay Card MCB
113.
[106] Relay 5
X47/VLT
®
Extended Relay Card MCB
113.
[107] Relay 6
X47/VLT
®
Extended Relay Card MCB
113.
[108] Relay 7
X34/VLT
®
Relay Card MCB 105.
[109] Relay 8
X34/VLT
®
Relay Card MCB 105.
[110] Relay 9
X34/VLT
®
Relay Card MCB 105.
[222] Homing Ok
NOTICE
This option is available only with
software version 48.20 and
newer.
Homing is completed with the
selected homing function
(
parameter 17-80 Homing Function
[223] On Target
NOTICE
This option is available only with
software version 48.20 and
newer.
13-40 Logic Rule Boolean 1
Option:
Function:
Positioning is completed and the on
target signal is sent when the actual
position is within
for the duration of
and the
actual speed does not exceed
parameter 3-05 On Reference Window
.
[224] Position Error
NOTICE
This option is available only with
software version 48.20 and
newer.
The position error exceeds the value
in
parameter 4-71 Maximum Position
for the time set in
parameter 4-72 Position Error Timeout
[225] Position Limit
NOTICE
This option is available only with
software version 48.20 and
newer.
The position is outside the limits set
in
parameter 3-06 Minimum Position
and
parameter 3-07 Maximum Position
[226] Touch on Target
NOTICE
This option is available only with
software version 48.20 and
newer.
Target position is reached in touch
probe position mode.
[227] Touch Activated
NOTICE
This option is available only with
software version 48.20 and
newer.
Touch probe positioning active. The
frequency converter monitors the
touch probe sensor input.
13-41 Logic Rule Operator 1
Array [6]
Option:
Function:
Select the 1
st
logical operator to use on the
boolean inputs from
and
.
Parameter numbers in square brackets stand
for the boolean inputs of parameters in
parameter group 13-** Smart Logic Control
.
Parameter Descriptions
Programming Guide
MG33MP02