5-53 Term. 29 High Ref./Feedb. Value
ExpressionLimit
All set-ups
x
TRUE
-3
Int32
5-54 Pulse Filter Time Constant #29
100 ms
All set-ups
x
FALSE
-3
Uint16
5-55 Term. 33 Low Frequency
100 Hz
All set-ups
TRUE
0
Uint32
5-56 Term. 33 High Frequency
ExpressionLimit
All set-ups
TRUE
0
Uint32
5-57 Term. 33 Low Ref./Feedb. Value
0 ReferenceFeedbackUnit
All set-ups
TRUE
-3
Int32
5-58 Term. 33 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
5-59 Pulse Filter Time Constant #33
100 ms
All set-ups
FALSE
-3
Uint16
5-6* Pulse Output
5-60 Terminal 27 Pulse Output Variable
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-62 Pulse Output Max Freq #27
ExpressionLimit
All set-ups
TRUE
0
Uint32
5-63 Terminal 29 Pulse Output Variable
ExpressionLimit
All set-ups
x
TRUE
-
Uint8
5-65 Pulse Output Max Freq #29
ExpressionLimit
All set-ups
x
TRUE
0
Uint32
5-66 Terminal X30/6 Pulse Output Variable
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-68 Pulse Output Max Freq #X30/6
ExpressionLimit
All set-ups
TRUE
0
Uint32
5-7* 24V Encoder Input
5-70 Term 32/33 Pulses Per Revolution
1024 N/A
All set-ups
FALSE
0
Uint16
5-71 Term 32/33 Encoder Direction
[0] Clockwise
All set-ups
FALSE
-
Uint8
5-8* I/O Options
5-80 AHF Cap Reconnect Delay
25 s
2 set-ups
x
TRUE
0
Uint16
5-9* Bus Controlled
5-90 Digital & Relay Bus Control
0 N/A
All set-ups
TRUE
0
Uint32
5-93 Pulse Out #27 Bus Control
0 %
All set-ups
TRUE
-2
N2
5-94 Pulse Out #27 Timeout Preset
0 %
1 set-up
TRUE
-2
Uint16
5-95 Pulse Out #29 Bus Control
0 %
All set-ups
x
TRUE
-2
N2
5-96 Pulse Out #29 Timeout Preset
0 %
1 set-up
x
TRUE
-2
Uint16
5-97 Pulse Out #X30/6 Bus Control
0 %
All set-ups
TRUE
-2
N2
5-98 Pulse Out #X30/6 Timeout Preset
0 %
1 set-up
TRUE
-2
Uint16
5.2.7 6-** Analog In/Out
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
6-0* Analog I/O Mode
6-00 Live Zero Timeout Time
10 s
All set-ups
TRUE
0
Uint8
6-01 Live Zero Timeout Function
[0] Off
All set-ups
TRUE
-
Uint8
6-1* Analog Input 1
6-10 Terminal 53 Low Voltage
ExpressionLimit
All set-ups
TRUE
-2
Int16
6-11 Terminal 53 High Voltage
10 V
All set-ups
TRUE
-2
Int16
6-12 Terminal 53 Low Current
0.14 mA
All set-ups
TRUE
-5
Int16
6-13 Terminal 53 High Current
20 mA
All set-ups
TRUE
-5
Int16
6-14 Terminal 53 Low Ref./Feedb. Value
0 ReferenceFeedbackUnit
All set-ups
TRUE
-3
Int32
6-15 Terminal 53 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
6-16 Terminal 53 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
6-2* Analog Input 2
6-20 Terminal 54 Low Voltage
ExpressionLimit
All set-ups
TRUE
-2
Int16
6-21 Terminal 54 High Voltage
10 V
All set-ups
TRUE
-2
Int16
6-22 Terminal 54 Low Current
ExpressionLimit
All set-ups
TRUE
-5
Int16
6-23 Terminal 54 High Current
20 mA
All set-ups
TRUE
-5
Int16
6-24 Terminal 54 Low Ref./Feedb. Value
0 ReferenceFeedbackUnit
All set-ups
TRUE
-3
Int32
6-25 Terminal 54 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
6-26 Terminal 54 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
6-3* Analog Input 3
6-30 Terminal X30/11 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
6-31 Terminal X30/11 High Voltage
10 V
All set-ups
TRUE
-2
Int16
Parameter Lists
VLT
®
AutomationDrive FC 301/302
270