8-91 Bus Jog 2 Speed
ExpressionLimit
All set-ups
TRUE
67
Uint16
5.3.10 9-** PROFIdrive
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
9-00 Setpoint
0 N/A
All set-ups
TRUE
0
Uint16
9-07 Actual Value
0 N/A
All set-ups
FALSE
0
Uint16
9-15 PCD Write Configuration
ExpressionLimit
1 set-up
TRUE
-
Uint16
9-16 PCD Read Configuration
ExpressionLimit
2 set-ups
TRUE
-
Uint16
9-18 Node Address
126 N/A
1 set-up
TRUE
0
Uint8
9-19 Drive Unit System Number
1034 N/A
All set-ups
TRUE
0
Uint16
9-22 Telegram Selection
[100] None
1 set-up
TRUE
-
Uint8
9-23 Parameters for Signals
0
All set-ups
TRUE
-
Uint16
9-27 Parameter Edit
[1] Enabled
2 set-ups
FALSE
-
Uint16
9-28 Process Control
[1] Enable cyclic master
2 set-ups
FALSE
-
Uint8
9-44 Fault Message Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-45 Fault Code
0 N/A
All set-ups
TRUE
0
Uint16
9-47 Fault Number
0 N/A
All set-ups
TRUE
0
Uint16
9-52 Fault Situation Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-53 Profibus Warning Word
0 N/A
All set-ups
TRUE
0
V2
9-63 Actual Baud Rate
[255] No baudrate found
All set-ups
TRUE
-
Uint8
9-64 Device Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-65 Profile Number
0 N/A
All set-ups
TRUE
0
OctStr[
2]
9-67 Control Word 1
0 N/A
All set-ups
TRUE
0
V2
9-68 Status Word 1
0 N/A
All set-ups
TRUE
0
V2
9-70 Edit Set-up
[1] Set-up 1
All set-ups
TRUE
-
Uint8
9-71 Profibus Save Data Values
[0] Off
All set-ups
TRUE
-
Uint8
9-72 ProfibusDriveReset
[0] No action
1 set-up
FALSE
-
Uint8
9-75 DO Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-80 Defined Parameters (1)
0 N/A
All set-ups
FALSE
0
Uint16
9-81 Defined Parameters (2)
0 N/A
All set-ups
FALSE
0
Uint16
9-82 Defined Parameters (3)
0 N/A
All set-ups
FALSE
0
Uint16
9-83 Defined Parameters (4)
0 N/A
All set-ups
FALSE
0
Uint16
9-84 Defined Parameters (5)
0 N/A
All set-ups
FALSE
0
Uint16
9-85 Defined Parameters (6)
0 N/A
All set-ups
FALSE
0
Uint16
9-90 Changed Parameters (1)
0 N/A
All set-ups
FALSE
0
Uint16
9-91 Changed Parameters (2)
0 N/A
All set-ups
FALSE
0
Uint16
9-92 Changed Parameters (3)
0 N/A
All set-ups
FALSE
0
Uint16
9-93 Changed Parameters (4)
0 N/A
All set-ups
FALSE
0
Uint16
9-94 Changed Parameters (5)
0 N/A
All set-ups
FALSE
0
Uint16
9-99 Profibus Revision Counter
0 N/A
All set-ups
TRUE
0
Uint16
5.3.11 10-** CAN Fieldbus
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
10-0* Common Settings
10-00 CAN Protocol
ExpressionLimit
2 set-ups
FALSE
-
Uint8
10-01 Baud Rate Select
ExpressionLimit
2 set-ups
TRUE
-
Uint8
10-02 MAC ID
ExpressionLimit
2 set-ups
TRUE
0
Uint8
10-05 Readout Transmit Error Counter
0 N/A
All set-ups
TRUE
0
Uint8
10-06 Readout Receive Error Counter
0 N/A
All set-ups
TRUE
0
Uint8
Parameter Lists
VLT
®
AutomationDrive FC 301/302
304
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02
5
5