7-18 Torque PI Feed Forward Factor
0 %
All set-ups
TRUE
0
Uint16
7-19 Current Controller Rise Time
ExpressionLimit
All set-ups
TRUE
0
Uint16
7-2* Process Ctrl. Feedb
7-20 Process CL Feedback 1 Resource
[0] No function
All set-ups
TRUE
-
Uint8
7-22 Process CL Feedback 2 Resource
[0] No function
All set-ups
TRUE
-
Uint8
7-3* Process PID Ctrl.
7-30 Process PID Normal/ Inverse Control
[0] Normal
All set-ups
TRUE
-
Uint8
7-31 Process PID Anti Windup
[1] On
All set-ups
TRUE
-
Uint8
7-32 Process PID Start Speed
0 RPM
All set-ups
TRUE
67
Uint16
7-33 Process PID Proportional Gain
ExpressionLimit
All set-ups
TRUE
-2
Uint16
7-34 Process PID Integral Time
10000 s
All set-ups
TRUE
-2
Uint32
7-35 Process PID Differentiation Time
0 s
All set-ups
TRUE
-2
Uint16
7-36 Process PID Diff. Gain Limit
5 N/A
All set-ups
TRUE
-1
Uint16
7-38 Process PID Feed Forward Factor
0 %
All set-ups
TRUE
0
Uint16
7-39 On Reference Bandwidth
5 %
All set-ups
TRUE
0
Uint8
7-4* Adv. Process PID I
7-40 Process PID I-part Reset
[0] No
All set-ups
TRUE
-
Uint8
7-41 Process PID Output Neg. Clamp
-100 %
All set-ups
TRUE
0
Int16
7-42 Process PID Output Pos. Clamp
100 %
All set-ups
TRUE
0
Int16
7-43 Process PID Gain Scale at Min. Ref.
100 %
All set-ups
TRUE
0
Int16
7-44 Process PID Gain Scale at Max. Ref.
100 %
All set-ups
TRUE
0
Int16
7-45 Process PID Feed Fwd Resource
[0] No function
All set-ups
TRUE
-
Uint8
7-46 Process PID Feed Fwd Normal/ Inv. Ctrl.
[0] Normal
All set-ups
TRUE
-
Uint8
7-48 PCD Feed Forward
0 N/A
All set-ups
x
TRUE
0
Uint16
7-49 Process PID Output Normal/ Inv. Ctrl.
[0] Normal
All set-ups
TRUE
-
Uint8
7-5* Adv. Process PID II
7-50 Process PID Extended PID
[1] Enabled
All set-ups
TRUE
-
Uint8
7-51 Process PID Feed Fwd Gain
1 N/A
All set-ups
TRUE
-2
Uint16
7-52 Process PID Feed Fwd Ramp up
0.01 s
All set-ups
TRUE
-2
Uint32
7-53 Process PID Feed Fwd Ramp down
0.01 s
All set-ups
TRUE
-2
Uint32
7-56 Process PID Ref. Filter Time
0.001 s
All set-ups
TRUE
-3
Uint16
7-57 Process PID Fb. Filter Time
0.001 s
All set-ups
TRUE
-3
Uint16
5.2.9 8-** Comm. and Options
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
8-0* General Settings
8-01 Control Site
[0] Digital and ctrl.word
All set-ups
TRUE
-
Uint8
8-02 Control Word Source
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-03 Control Word Timeout Time
1 s
1 set-up
TRUE
-1
Uint32
8-04 Control Word Timeout Function
ExpressionLimit
1 set-up
TRUE
-
Uint8
8-05 End-of-Timeout Function
[1] Resume set-up
1 set-up
TRUE
-
Uint8
8-06 Reset Control Word Timeout
[0] Do not reset
All set-ups
TRUE
-
Uint8
8-07 Diagnosis Trigger
[0] Disable
2 set-ups
TRUE
-
Uint8
8-08 Readout Filtering
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-1* Ctrl. Word Settings
8-10 Control Word Profile
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-13 Configurable Status Word STW
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-14 Configurable Control Word CTW
[1] Profile default
2 set-ups
TRUE
-
Uint8
8-17 Configurable Alarm and Warningword
[0] Off
All set-ups
TRUE
-
Uint16
8-19 Product Code
ExpressionLimit
1 set-up
TRUE
0
Uint32
8-3* FC Port Settings
8-30 Protocol
[0] FC
1 set-up
TRUE
-
Uint8
8-31 Address
1 N/A
1 set-up
TRUE
0
Uint8
Parameter Lists
VLT
®
AutomationDrive FC 301/302
272