8-40 Telegram Selection
Option:
Function:
[105] PPO 5
[106] PPO 6
[107] PPO 7
[108] PPO 8
[200] Custom telegram 1
Enables use of freely configurable
telegrams or standard telegrams for
the FC port.
[202] Custom telegram 3
8-41 Parameters for Signals
Option:
Function:
[0]
*
None
[15]
Readout: actual setup
[302]
Minimum Reference
[303]
Maximum Reference
[312]
Catch up/slow Down Value
[321]
Touch Target
[322]
Master Scale Numerator
[323]
Master Scale Denominator
[326]
Master Offset
[328]
Master Offset Speed Ref
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog/Homing Ramp Time
[381]
Quick Stop Ramp Time
[411]
Motor Speed Low Limit [RPM]
[412]
Motor Speed Low Limit [Hz]
[413]
Motor Speed High Limit [RPM]
[414]
Motor Speed High Limit [Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[482]
Power Limit Motor Mode
[483]
Power Limit Generator Mode
[491]
Positive Speed Limit [RPM]
[492]
Positive Speed Limit [Hz]
[493]
Negative Speed Limit [RPM]
[494]
Negative Speed Limit [Hz]
[495]
Positive Torque limit
[496]
Negative Torque limit
[553]
Term. 29 High Ref./Feedb. Value
[558]
Term. 33 High Ref./Feedb. Value
[590]
Digital & Relay Bus Control
[593]
Pulse Out #27 Bus Control
[595]
Pulse Out #29 Bus Control
[597]
Pulse Out #X30/6 Bus Control
[615]
Terminal 53 High Ref./Feedb. Value
[625]
Terminal 54 High Ref./Feedb. Value
[653]
Term 42 Output Bus Ctrl
[663]
Terminal X30/8 Bus Control
[673]
Terminal X45/1 Bus Control
8-41 Parameters for Signals
Option:
Function:
[683]
Terminal X45/3 Bus Control
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[1397]
Alert Alarm Word
[1398]
Alert Warning Word
[1399]
Alert Status Word
[1472]
Legacy Alarm Word
[1473]
Legacy Warning Word
[1474]
Leg. Ext. Status Word
[1500]
Operating hours
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference %
[1603]
Status Word
[1605]
Main Actual Value [%]
[1606]
Actual Position
[1607]
Target Position
[1608]
Position Error
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1617]
Speed [RPM]
[1618]
Motor Thermal
[1619]
Thermistor Sensor Temperature
[1620]
Motor Angle
[1621]
Torque [%] High Res.
[1622]
Torque [%]
[1623]
Motor Shaft Power [kW]
[1624]
Calibrated Stator Resistance
[1625]
Torque [Nm] High
[1628]
Angle Error
[1630]
DC Link Voltage
[1632]
Brake Energy /s
[1633]
Brake Energy Average
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1638]
SL Controller State
[1639]
Control Card Temp.
[1642]
Service Log Counter
[1644]
Speed Error [RPM]
[1645]
Motor Phase U Current
[1646]
Motor Phase V Current
[1647]
Motor Phase W Current
[1648]
Speed Ref. After Ramp [RPM]