14-14 Kin. Back-up Time-out
60 s
All set-ups
TRUE
0
Uint8
14-15 Kin. Back-up Trip Recovery Level
ExpressionLimit
All set-ups
TRUE
-3
Uint32
14-16 Kin. Back-up Gain
100 %
All set-ups
x
TRUE
0
Uint32
14-2* Trip Reset
14-20 Reset Mode
[0] Manual reset
All set-ups
TRUE
-
Uint8
14-21 Automatic Restart Time
ExpressionLimit
All set-ups
TRUE
0
Uint16
14-22 Operation Mode
[0] Normal operation
All set-ups
TRUE
-
Uint8
14-23 Typecode Setting
ExpressionLimit
2 set-ups
FALSE
-
Uint16
14-24 Trip Delay at Current Limit
60 s
All set-ups
TRUE
0
Uint8
14-25 Trip Delay at Torque Limit
60 s
All set-ups
TRUE
0
Uint8
14-26 Trip Delay at Inverter Fault
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-28 Production Settings
[0] No action
All set-ups
TRUE
-
Uint8
14-29 Service Code
0 N/A
All set-ups
TRUE
0
Int32
14-3* Current Limit Ctrl.
14-30 Current Lim Ctrl, Proportional Gain
100 %
All set-ups
FALSE
0
Uint16
14-31 Current Lim Ctrl, Integration Time
ExpressionLimit
All set-ups
FALSE
-3
Uint16
14-32 Current Lim Ctrl, Filter Time
ExpressionLimit
All set-ups
TRUE
-4
Uint16
14-35 Stall Protection
[1] Enabled
All set-ups
FALSE
-
Uint8
14-36 Field-weakening Function
[0] Auto
All set-ups
x
TRUE
-
Uint8
14-37 Fieldweakening Speed
ExpressionLimit
All set-ups
x
TRUE
67
Uint16
14-4* Energy Optimising
14-40 VT Level
66 %
All set-ups
FALSE
0
Uint8
14-41 AEO Minimum Magnetisation
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-42 Minimum AEO Frequency
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-43 Motor Cosphi
ExpressionLimit
All set-ups
TRUE
-2
Uint16
14-44 d-axis Reference Gain
100 %
All set-ups
TRUE
0
Uint8
14-5* Environment
14-50 RFI Filter
[1] On
1 set-up
FALSE
-
Uint8
14-51 DC-Link Compensation
ExpressionLimit
All set-ups
TRUE
-
Uint8
14-52 Fan Control
[0] Auto
All set-ups
TRUE
-
Uint8
14-53 Fan Monitor
[1] Warning
All set-ups
TRUE
-
Uint8
14-55 Output Filter
[0] No Filter
All set-ups
FALSE
-
Uint8
14-56 Capacitance Output Filter
ExpressionLimit
All set-ups
FALSE
-7
Uint16
14-57 Inductance Output Filter
ExpressionLimit
All set-ups
FALSE
-6
Uint16
14-59 Actual Number of Inverter Units
ExpressionLimit
1 set-up
x
FALSE
0
Uint8
14-6* Auto Derate
14-60 Function at Over Temperature
[0] Trip
All set-ups
TRUE
-
Uint8
14-61 Function at Inverter Overload
[0] Trip
All set-ups
TRUE
-
Uint8
14-62 Inv. Overload Derate Current
95 %
All set-ups
TRUE
0
Uint16
14-7* Compatibility
14-72 Legacy Alarm Word
0 N/A
All set-ups
FALSE
0
Uint32
14-73 Legacy Warning Word
0 N/A
All set-ups
FALSE
0
Uint32
14-74 Leg. Ext. Status Word
0 N/A
All set-ups
FALSE
0
Uint32
14-8* Options
14-80 Option Supplied by External 24VDC
[1] Yes
2 set-ups
FALSE
-
Uint8
14-88 Option Data Storage
0 N/A
2 set-ups
TRUE
0
Uint16
14-89 Option Detection
[0] Protect Option Config.
1 set-up
TRUE
-
Uint8
14-9* Fault Settings
14-90 Fault Level
ExpressionLimit
1 set-up
TRUE
-
Uint8
5.3.15 15-** Drive Information
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
Parameter Lists
VLT
®
AutomationDrive FC 301/302
308
Danfoss A/S © 10/2018 All rights reserved.