0-20 Display Line 1.1 Small
Option:
Function:
[1602] Reference %
Total reference (sum of digital/
analog/preset/bus/freeze reference./
catch up and slow down) in percent.
[1603] Status Word
Present status word.
[1605] Main Actual Value
[%]
Actual value as a percentage.
[1606] Actual Position
Actual position in position units
selected in
[1607] Target Position
Active target position in position
units selected in
.
[1608] Position Error
Actual position PI error in position
units selected in
.
[1609] Custom Readout
[1610] Power [kW]
Actual power consumed by the
motor in kW.
[1611] Power [hp]
Actual power consumed by the
motor in hp.
[1612] Motor Voltage
Voltage supplied to the motor.
[1613] Frequency
Motor frequency, that is the output
frequency from the frequency
converter in Hz.
[1614] Motor current
Phase current of the motor
measured as effective value.
[1615] Frequency [%]
Motor frequency, that is the output
frequency from the frequency
converter in percent.
[1616] Torque [Nm]
Actual motor torque in Nm.
[1617] Speed [RPM]
Speed in RPM (revolutions per
minute), that is the motor shaft
speed in closed loop.
[1618] Motor Thermal
Thermal load on the motor,
calculated by the ETR function.
[1619] Thermistor Sensor
Temperature
[1620] Motor Angle
[1621] Torque [%] High
Res.
[1622] Torque [%]
Present motor load as a percentage
of the rated motor torque.
[1623] Motor Shaft Power
[kW]
[1624] Calibrated Stator
Resistance
[1625] Torque [Nm] High
[1628] Angle Error
0-20 Display Line 1.1 Small
Option:
Function:
[1630] DC Link Voltage
DC-link voltage in the frequency
converter.
[1631] System Temp.
[1632] Brake Energy /s
Present brake power transferred to
an external brake resistor.
Stated as an instant value.
[1633] Brake Energy
Average
Brake power transferred to an
external brake resistor. The mean
power is calculated continuously for
the most recent 120 s.
[1634] Heatsink Temp.
Present heat sink temperature of the
frequency converter. The cutout
limit is 95
±
5
°
C (203
±
9
°
F); cutting
back in occurs at 70
±
5
°
C
(203
±
9
°
F).
[1635] Inverter Thermal
Percentage load of the inverters.
[1636] Inv. Nom. Current
Nominal current of the frequency
converter.
[1637] Inv. Max. Current
Maximum current of the frequency
converter.
[1638] SL Controller State
State of the event executed by the
control.
[1639] Control Card Temp. Temperature of the control card.
[1642] Service Log
Counter
[1643] Timed Actions
Status
[1644] Speed Error [RPM]
[1645] Motor Phase U
Current
[1646] Motor Phase V
Current
[1647] Motor Phase W
Current
[1648] Speed Ref. After
Ramp [RPM]
[1650] External Reference
Sum of the external reference as a
percentage, that is the sum of
analog/pulse/bus.
[1651] Pulse Reference
Frequency in Hz connected to the
digital inputs (18, 19 or 32, 33).
[1652] Feedback[Unit]
Reference value from programmed
digital inputs.
[1653] Digi Pot Reference
[1657] Feedback [RPM]
[1660] Digital Input
Signal states from the 6 digital
terminals (18, 19, 27, 29, 32, and
33). There are 16 bits in total, but
only 6 of them are used. Input 18
Parameter Descriptions
VLT
®
AutomationDrive FC 301/302
28
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02