0-89 Date and Time Readout
0 N/A
All set-ups
TRUE
0
VisStr[
25]
5.3.2 1-** Load and Motor
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
1-0* General Settings
1-00 Configuration Mode
ExpressionLimit
All set-ups
TRUE
-
Uint8
1-01 Motor Control Principle
ExpressionLimit
All set-ups
FALSE
-
Uint8
1-02 Flux Motor Feedback Source
[1] 24V encoder 32/33
All set-ups
x
FALSE
-
Uint8
1-03 Torque Characteristics
[0] Constant torque
All set-ups
TRUE
-
Uint8
1-04 Overload Mode
[0] High torque
All set-ups
FALSE
-
Uint8
1-05 Local Mode Configuration
[2] As mode par 1-00
All set-ups
TRUE
-
Uint8
1-06 Clockwise Direction
[0] Normal
All set-ups
FALSE
-
Uint8
1-07 Motor Angle Offset Adjust
[0] Manual
All set-ups
x
FALSE
-
Uint8
1-1* Special Settings
1-10 Motor Construction
[0] Asynchron
All set-ups
FALSE
-
Uint8
1-11 Motor Model
ExpressionLimit
All set-ups
x
FALSE
-
Uint8
1-14 Damping Gain
140 %
All set-ups
TRUE
0
Int16
1-15 Low Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-16 High Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-17 Voltage filter time const.
ExpressionLimit
All set-ups
TRUE
-3
Uint16
1-18 Min. Current at No Load
0 %
All set-ups
TRUE
0
Uint16
1-2* Motor Data
1-20 Motor Power [kW]
ExpressionLimit
All set-ups
FALSE
1
Uint32
1-21 Motor Power [HP]
ExpressionLimit
All set-ups
FALSE
-2
Uint32
1-22 Motor Voltage
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-23 Motor Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-24 Motor Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
1-25 Motor Nominal Speed
ExpressionLimit
All set-ups
FALSE
67
Uint16
1-26 Motor Cont. Rated Torque
ExpressionLimit
All set-ups
FALSE
-1
Uint32
1-29 Automatic Motor Adaptation (AMA)
[0] Off
All set-ups
FALSE
-
Uint8
1-3* Adv. Motor Data
1-30 Stator Resistance (Rs)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-31 Rotor Resistance (Rr)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-33 Stator Leakage Reactance (X1)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-34 Rotor Leakage Reactance (X2)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-35 Main Reactance (Xh)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-36 Iron Loss Resistance (Rfe)
ExpressionLimit
All set-ups
FALSE
-3
Uint32
1-37 d-axis Inductance (Ld)
ExpressionLimit
All set-ups
x
FALSE
-4
Int32
1-38 q-axis Inductance (Lq)
ExpressionLimit
All set-ups
x
FALSE
-6
Int32
1-39 Motor Poles
ExpressionLimit
All set-ups
FALSE
0
Uint8
1-40 Back EMF at 1000 RPM
ExpressionLimit
All set-ups
x
FALSE
0
Uint16
1-41 Motor Angle Offset
0 N/A
All set-ups
TRUE
0
Int16
1-44 d-axis Inductance Sat. (LdSat)
ExpressionLimit
All set-ups
x
FALSE
-6
Int32
1-45 q-axis Inductance Sat. (LqSat)
ExpressionLimit
All set-ups
x
FALSE
-6
Int32
1-46 Position Detection Gain
120 %
All set-ups
TRUE
0
Uint16
1-47 Torque Calibration
ExpressionLimit
All set-ups
TRUE
-
Uint8
1-48 d-axis Inductance Sat. Point
ExpressionLimit
All set-ups
x
TRUE
0
Int16
1-49 q-axis Inductance Sat. Point
ExpressionLimit
All set-ups
x
FALSE
0
Uint16
1-5* Load Indep. Setting
1-50 Motor Magnetisation at Zero Speed
100 %
All set-ups
TRUE
0
Uint16
1-51 Min Speed Normal Magnetising [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
1-52 Min Speed Normal Magnetising [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
Parameter Lists
VLT
®
AutomationDrive FC 301/302
294
Danfoss A/S © 10/2018 All rights reserved.