Thermistor Resistance / Temperature Characteristics
SiUS181305E
225
Troubleshooting
Table 2
Applicable
thermistor
Outdoor unit
FINTH: Radiation fin
Outdoor unit
R2T: Discharge pipe
Thermistor
temperature
°C (°F)
Resistance (k
)
Resistance (k
)
–30 (–22)
354.1
4759
–25 (–13)
259.7
3454
–20 (–4)
192.6
2534
–15 (5)
144.2
1877
–10 (14)
109.1
1404
–5 (23)
83.25
1059
0 (32)
64.10
806.5
5 (41)
49.70
618.9
10 (50)
38.85
478.8
15 (59)
30.61
373.1
20 (68)
24.29
292.9
25 (77)
19.41
231.4
30 (86)
15.61
184.1
35 (95)
12.64
147.4
40 (104)
10.30
118.7
45 (113)
8.439
96.13
50 (122)
6.954
78.29
55 (131)
5.761
64.10
60 (140)
4.797
52.76
65 (149)
4.014
43.63
70 (158)
3.375
36.26
75 (167)
2.851
30.27
80 (176)
2.418
25.38
85 (185)
2.060
21.37
90 (194)
1.762
18.06
95 (203)
1.513
15.33
100 (212)
1.304
13.06
105 (221)
1.128
11.17
110 (230)
0.9790
9.585
115 (239)
0.8527
8.254
120 (248)
0.7450
7.131
125 (257)
0.6530
6.181
130 (266)
0.5741
5.374
135 (275)
–
4.686
140 (284)
–
4.098
145 (293)
–
3.594
150 (302)
–
3.161
Drawing No.
3PA61998
(AD92A057)
3SA48009
(AD970175)
Содержание RMXS-L Series
Страница 10: ...Safety Considerations Safety Considerations ix...
Страница 11: ...SiUS181305E 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 Outdoor Unit 2 1 2 Indoor Unit 3...
Страница 129: ...SiUS181305E Field Settings Test Operation and Field Settings 120...
Страница 144: ...FFQ09 12 15 18LVJU SiUS181305E 135 Remote Controller...
Страница 249: ...SiUS181305E Removal Procedure Booklet No Appendix 240...