SiUS181305E
Function of CTXS, FTXS, CDXS, FDXS Series
Function
64
3-D Airflow
Alternative repetition of vertical and horizontal swing motions enables uniform airconditioning of the
entire room. This function is effective for starting the air conditioner.
When the horizontal swing and vertical swing are both set to automatic operation, the airflow
becomes 3-D airflow. The horizontal and vertical swing motions are alternated and the airflow
direction changes in the order shown in the following diagram.
(1) The vertical blades (fins) move from the right to the left.
(2) The horizontal blades (louvers) move downward.
(3) The vertical blades (fins) move from the left to the right.
(4) The horizontal blades (louvers) move upward.
COMFORT
AIRFLOW
Operation
CTXS-L, FTXS-L Series
The horizontal blades (louvers) are controlled not to blow the air directly at the people in the room.
(R13554)
(1)
(4)
(3)
(2)
Cooling
Heating
CTXS07LVJU
FTXS15/18/
24LVJU
(R4302)
8˚
(R8413)
80˚
(R9655)
10
°
10
°
(R9654)
75
°
80
°