Function of CTXS, FTXS, CDXS, FDXS Series
SiUS181305E
69
Function
7.7
NIGHT SET Mode
Outline
When the OFF timer is set, the NIGHT SET Mode is automatically activated. The NIGHT SET
Mode keeps the airflow rate setting.
Detail
The NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in cooling, or lowers it slightly in heating. This
prevents excessive cooling or heating to ensure comfortable sleeping conditions, and also
conserves electricity.
<Cooling>
<Heating>
7.8
ECONO Operation
Outline
CTXS-L, FTXS-L, CDXS-L, FDXS-L Series
ECONO operation reduces the maximum operating current and the power consumption.
Detail
When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in COOL, HEAT, DRY, or
AUTO operation. This function can only be set when the unit is running. Pressing the
ON/OFF
button on the remote controller cancels the function.
This function and POWERFUL operation cannot be used at the same time. The latest command
has the priority.
(R18809)
TIMER operation
NIGHT SET Mode ON
Target temperature
+0.5˚C (+0.9˚F)
temperature shift
Operation stops
at the set hours
1 hour
0.5˚C (0.9˚F)
TIMER operation
NIGHT SET Mode ON
Target temperature
–2˚C (–3.6˚F)
temperature shift
1 hour
2˚C (3.6˚F)
(R19113)
ECONO Operation
(R9288)
Normal
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current
Содержание RMXS-L Series
Страница 10: ...Safety Considerations Safety Considerations ix...
Страница 11: ...SiUS181305E 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 Outdoor Unit 2 1 2 Indoor Unit 3...
Страница 129: ...SiUS181305E Field Settings Test Operation and Field Settings 120...
Страница 144: ...FFQ09 12 15 18LVJU SiUS181305E 135 Remote Controller...
Страница 249: ...SiUS181305E Removal Procedure Booklet No Appendix 240...