SiUS181305E
Field Settings
Test Operation and Field Settings
118
Wireless Remote
Controller
(Factory Set is 1)
1. Hold down the
FILTER SIGN RESET
(
) button and the
INSPECTION/TEST
button at the
same time for at least 4 seconds to enter the field setting mode. (SETTING is indicated on the
display).
2. Press the
FAN
button and select A or b. Each time the button is pressed, the display switches
between A and b.
3. Press the
UP
button and
DOWN
button to set the address.
Address can be set from 1 ~ 6, but set it to 1 ~ 3 and to same address as the receiver. (The
receiver does not work with address 4 ~ 6.)
4. Press the
RESERVE
button to confirm the setting.
5. Hold down the
INSPECTION/TEST
button for at least 1 second to exit the field setting mode
and return to the normal display.
Multiple Settings
A/b
When the indoor is controlled by outside controller (central remote controller, etc.), it sometimes
does not respond to ON/OFF command or temperature setting command from the remote
controller. Check what setting the customer needs and make the multiple setting as shown below.
Field setting mode
Address
Multiple setting
(R14401)
Remote Controller
Indoor Unit
Multiple Setting
Remote Controller
Display
Controlled by other air
conditioners or devices
Other condition
A: Standard
All items are displayed.
ON/OFF command and
temperature setting
command cannot be
accepted. (1 long beep or
3 short beeps emitted)
b: Multiple display
Operations set only is
displayed shortly after
execution.
All the commands can be accepted (2 short beeps)
Содержание RMXS-L Series
Страница 10: ...Safety Considerations Safety Considerations ix...
Страница 11: ...SiUS181305E 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 Outdoor Unit 2 1 2 Indoor Unit 3...
Страница 129: ...SiUS181305E Field Settings Test Operation and Field Settings 120...
Страница 144: ...FFQ09 12 15 18LVJU SiUS181305E 135 Remote Controller...
Страница 249: ...SiUS181305E Removal Procedure Booklet No Appendix 240...