Use the following table to check the status of the Interlock LEDs and to further
troubleshoot any power problems.
Table 3-3
System Interlock LEDs
AUX 5
Volt
Syste
m
Processor Board
Status
OFF
OFF
OFF
No power to the interlock.
Follow the steps in the “Troubleshooting
Interlock Power” section.
ON
OFF
OFF
System interlock status is normal.
OR
1.
If the server will not power up, then the I/O
board power cable is disconnected from the
I/O board or the power backplane. Verify the
power cable is not damaged and is properly
installed to the I/O board and the power
backplane board.
2.
A software shutdown will place the server in
Standby even when the On/Standby switch is
in the ON position. This is normal. To turn the
server back on, toggle the On/Standby switch
to STANDBY and then ON. The server should
power up within 15 seconds of the toggle
event
ON
ON
OFF
Interlock connection is broken in the I/O area.
Follow the steps in the “Troubleshooting
System Connection” section.
ON
ON
ON
Interlock connection broken in the processor
area.
Follow the steps in the “Troubleshooting
Interlock Connection” section.