2-27
Compaq ProLiant 6000 Setup and Installation Guide
For use with Pentium II Xeon and Pentium III Xeon processor-based servers only
Writer: Sam Ogden Project: Compaq ProLiant 6000 Setup and Installation Guide Comments: 312237-003 (February 1999)
File Name: C-CH02.DOC Last Saved On: 2/4/99 1:18 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
5.
Carefully align the three screw holes on each side of the server and the
slide rail assembly. Attach the server to the slide rail assembly with six
8-32 slotted head screws.
CAUTION:
Be sure to keep the component parallel to the floor
when sliding the component rails into the slide rails. Tilting the
component up or down could result in damage to the rails.
Figure 2-18. Attaching the server
6.
Remove the rack lift assists. Store the rack lift assists and screws for
future use if the server needs to be removed from the rack.
WARNING:
To reduce the risk of personal injury, be careful
when pressing the component rail release latches and sliding the
component into the rack. The slide rails could pinch your
fingertips.
7.
Slide the server in and out of the rack several times to properly align the
slide rail assembly.
IMPORTANT:
The first time you slide the component into the rack, you
may have to apply some pressure. After the first time, the ball bearings in the
slide will move easily.
8.
Replace the top access panel.