4-20
Installing Hardware Options
For use with Pentium II Xeon and Pentium III Xeon processor-based servers only
Writer: Sam Ogden Project: Compaq ProLiant 6000 Setup and Installation Guide Comments: 312237-003 (February 1999)
File Name: E-CH04.DOC Last Saved On: 2/22/99 8:55 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
9.
Verify that the four DIMMs inserted are all within the same bank by
observing the bank boundaries outlined on the surface of the memory
expansion board.
4
3
2
1
Figure 4-18. Location of DIMM sockets for Banks 1-4
10.
Replace the memory expansion board. See “Removing and Replacing a
Memory Expansion Board” earlier in this chapter.
11.
Replace the right side access panel. See Chapter 3, “Server Operation.”
Reconnect the power cord(s).
NOTE
: The DIMMs are part of the system interlock chain and must be seated
properly for server start up. Ensure that the memory expansion board service
bracket is reinstalled after installing the DIMMs. For more information see the
“System Interlocks” section in Chapter 3, “Server Operation.”
12.
Turn on the server. See Chapter 2, “Server Installation and Start Up.”
13.
Verify that the memory was installed correctly by reviewing the POST
messages on the system console or memory information under the
System Information Menu of the IMD, if installed.