![Carrier VECTOR 6500 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/carrier/vector-6500/vector-6500_operation-and-service-manual_2563864054.webp)
62-11389
3
−
5
3.4 PRETRIP
COOL
DEFROST
ALARM
START‐STOP
SETPOINT
BOX TEMPERATURE
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT
CONTINUOUS
TEST #1
2. Press the SELECT key until the MessageCenter
displays “PRESS THE = KEY TO START PRETRIP” .
3. Press the = key to start Pretrip
4. Verify that during TEST#1 the complete display is turned on and that all lights on the Light Bar come
on. Verify during Test #2 that the that the buzzer comes on for the first five seconds.
5. The remainder of Pretrip will take 7 to 15 minutes, and will run itself automatically.
START‐STOP/
CONTINUOUS
1. Place the switch labeled ENGINE/OFF/STANDBY in the desired position
OR place the switch labeled START/RUN-OFF in the START/RUN position.
KEYPAD
+34.5 F
-20.0
XX% COMPLETE
Pretrip is a set of tests run by the microprocessor to
check unit operation. It is recommended that a Pretrip
be run prior to loading the trailer. It will indicate a failure
when one is detected.
TIP
A Pretrip can be started at any box temperat-
ure. If Pretrip is started while the unit is in a
Start-Stop off cycle the unit will start during the
course of the test. If the unit is running when
Pretrip is started, it will shutdown for the first
three tests.
TIP
It is always a good idea to clear all alarms from
both Alarm Lists before starting Pretrip. The
technician will then know that any alarms pres-
ent following Pretrip occurred during Pretrip,
and are not old alarms that had not been
cleared.
During the Pretrip test, the MessageCenter displays the
current test number and description and the % of the
test that has been completed. When Pretrip is complete
the MessageCenter will display one of three different
messages:
•
“PRETRIP PASS”
OR
•
“PRETRIP FAIL IN TEST X”
OR
•
“PRETRIP FAILED & COMPLETE”. Alarm light
will be on.
Press the ALARM LIST key to review the alarms
triggered by the Pretrip tests.
TIP
The Pretrip test “PASS” of “FAIL” results mes-
sage will stay displayed until any key is
pressed, or until the Main Power Switch is
placed in the OFF position.
Once Pretrip is started, the control panel keys are dis-