![Carrier VECTOR 6500 Скачать руководство пользователя страница 316](http://html1.mh-extra.com/html/carrier/vector-6500/vector-6500_operation-and-service-manual_2563864316.webp)
10
−
6
62-11389
10.2 HARNESS PLUG WIRING FOR UNITS WITH A MAIN POWER SWITCH LABELED START/RUN-OFF
1MP - NATURAL
1
12
24
35
Component
Terminal
REMSN1 (REMSN-E)
3 (14)
REMSN2 (REMSN-H)
4 (14)
CDP-C
5 (16) (30)
EVOP-C (DP16-S)
6 (17) (30)
ENCT
7 (18)
CDT
9 (20)
CST
10 (19)
AAT
11 (22)
1RAT (DP16-G)
12 (23)
REMSN1 (REMSN-F) (SP1)
14 (3)
REMSN2 (REMSN-G) (SP1)
14 (33)
REMSN3 (REMSN-K) (SP1)
14 (33)
1MP - NATURAL (Continued)
Component
Terminal
CSP-A (SP16)
15 (29) (30)
OGF-OV (HC-1) (SP16)
15
CDP-A
16 (5) (30)
EVOP-A (DP16-P)
17 (6) (30)
ENCT
18 (7)
CST (SP14)
19 (10)
EVOT (DP16-F) (SP14)
19 (32)
CDT
20 (9)
DTT (DP16-B)
21 (34)
AAT
22 (11)
1SAT (DP16-D) (SP12)
23 (35)
1RAT (DP16-H) (SP12)
23
FLS-C
26
CSP-C
29 (15) (30)
CSP-B (SP7)
30 (15) (29)
CDP-B (SP7)
30 (5) (16)
EVOP-B (SP7) (DP16-R)
30 (6) (17)
EVOT (DP16-E)
32 (19)
REMSN3 (REMSN-J)
33 (14)
2RAT (2EVC-J)
33 (23)
DTT (DP16-A)
34 (21)
1SAT (DP16-C)
35 (23)
Unused terminals: 1, 2,8,13,21, 24, 25, 27,28,31