62-11389
5
−
19
Table 5
−
2. Microprocessor Configurations - Continued
Configuration
Selections
Description
RANGE 1 LOCK
OR
RANGE 2 LOCK
OFF
START-STOP
CONTINUOUS
OFF = If both Range Locks are OFF, the unit will
operate normally.
If either Range 1 or Range 2 is not OFF, the unit
will operate as selected whenever the set point is
within that range
START-STOP = The unit will always operate in
Start-Stop whenever the setpoint is between the
minimum & maximum temperatures for that range
(see the following sub-configurations).
CONTINUOUS = The unit will always operate in
Continuous Run whenever the setpoint is between
the minimum & maximum temperatures for that
range (see the following sub-configurations).
•
RANGE 1 (or 2) MINIMUM
TEMPERATURE
-22
°
F TO
89.6
°
F
(-30
°
C to
32
°
C)
in 0.1
°
F or
°
C in-
crements
Select the lowest temperature desired for this
Range.
•
RANGE 1 (or 2) MAXIMUM
TEMPERATURE
-22
°
F TO
89.6
°
F
(-30
°
C to
32
°
C)
in 0.1
°
F or
°
C in-
crements
Select the highest temperature desired for this
range.
MIN SET POINT
-22
5
F
TO 89.6
°
F
(
-30
5
C
to 32
°
C)
in 0.1
°
F or
°
C in-
crements
Indicates to the microprocessor the desired minim-
um allowable set point .
MAX SET POINT
-22
°
F TO
89.6
5
F
(-30
°
C to
32
5
C
)
in 0.1
°
F or
°
C in-
crements
Indicates to the microprocessor the desired maxim-
um allowable set point.
NO A/C POWER
ALARM &
SHUTDOWN
SWITCH TO EN-
GINE
ALARM & SHUTDOWN = If standby power is lost
unit is to shutdown
SWITCH TO ENGINE = If standby power is lost
engine will be started.
S/S PARAMETERS
TOGETHER
SEPARATE
TOGETHER = When the Minimum Run Time, Mini-
mum Off Time, Restart Temperature, Maximum Off
Time, and Override Temperatures are set in the
Functional Parameter List, the same values will be
used for both Frozen and Perishable setpoints.
SEPARATE = When the Minimum Run Time, Mini-
mum Off Time, Restart Temperature, Maximum Off
Time, and Override Temperatures are set in the
Functional Parameter List, different values may be
entered for Perishable and Frozen setpoints.
REMOTE TEMP SENSOR 1 (or 2 or
3)
ON /
OFF
ON = A remote sensor has been added to the unit,
and connected into the wire harness.
OFF = There is no Remote Sensor (1or 2 or 3) in
this unit.