SECTION 6
MESSAGECENTER
6.1 MESSAGECENTER MESSAGES
The following table lists all of the messages which do not appear in other lists in this manual and a description of their
meaning. Refer to Section 7 for a list of alarm messages. Refer to Section 3.13 for a list of Unit Data messages. Refer
to Section 3.15 for a list of Functional Parameter messages. Refer to Section 5.2.1 for a list of Configuration
messages.
MessageCenter MESSAGES
Message
Description
↑↓
TO SCROLL, THEN = TO LOCK
This message is used when viewing Unit Data. Use the UP and
DOWN
arrow keys to move through the Data list. Press the = key
to lock a Data item in the MessageCenter.
↑↓
TO SCROLL, THEN = TO SAVE
Press the UP or DOWN arrow key to scroll through menu selec-
tions available in this mode. When you reach the desired selection,
press the = key to store new value in microprocessor’s memory.
↑↓
TO SCROLL, THEN = TO SELECT
Press the UP or DOWN arrow key to scroll through menu selec-
tions available in this mode. When you reach the desired selection,
press the = key to select it.
= TO INSTALL, INSTALLS LEFT XX
An Option PC Card has been inserted into the PC Card slot. Press
the = key to install the option into the microprocessor. The number
of installs remaining on the PC Card will be shown.
ACTIVE
This message will appear in the MessageCenter along with the cur-
rent IntelliSet indicating that the IntelliSet is active and none of its
settings have been modified.
ACTIVE ALARM LIST CLEARED
The list of active alarms in the microprocessor has been erased.
(This does
not
remove alarms from the DataLink data recorder.)
ALL ALARMS CLEARED
The list of active and inactive alarms in the microprocessor alarm
lists have been erased. (This does
not
remove alarms from the
DataLink data recorder.)
ALL INFO LOADED - REMOVE CARD
All data has been loaded into the microprocessor from the PC
Card. The card may be safely removed from the microprocessor.
BACK TO CONFIGS
Pressing the = key with this message showing will return the user
to the main microprocessor Configuration list.
BACK TO FUNC PARAMS
Pressing the = key with this message showing will return the user
to the main Functional Parameter list.
BAD PC CARD OR CARD SLOT
The microprocessor has detected a problem with either the PC
card or the PC card slot.
BUZZER OFF IN X MINS
The Buzzer circuit has been energized in Component Test Mode.
The Buzzer circuit will continue to be energized for the number of
minutes shown.
CALIBRATION UNSUCCESSFUL
An attempt to calibrate the discharge transducer failed.
CANNOT ENTER TRIP START
Cannot enter Trip Start. A problem has been detected within the
DataLink data recorder.
CANNOT START DEFROST CYCLE
Due to current unit conditions, the defrost cycle cannot be started.
Refer to Defrost Sections 3.9 and 8.8.9.
CANNOT START PRETRIP
Due to current unit conditions a Pretrip test cannot be started. Re-
fer to Pretrip Section 3.4.
CANNOT DOWNLOAD - BATTERY TOO
LOW
Data cannot be downloaded and software upgrades are prohibited
when battery voltage is below 7.0 volts. This message will be dis-
played until the serial cable is removed.
CARD FULL, REMOVE CARD
The PC Download Card is full. There is no additional room to down-
load information from the microprocessor. You may safely remove
the PC Card from the slot.