MessageCenter MESSAGES - Continued
Message
Description
DOOR OPEN - LOW SPEED
A refrigerated compartment door is open forcing the unit to run in
low speed.
ENTERING SERVICE MODE
The initial message for Service Mode.
ERROR: ENG HRS > SWITCH ON
HOURS
When setting up a replacement microprocessor, incorrect hours
have been entered
ERROR: HI SP HRS > TOTAL ENG
HOURS
ERROR: SBY HRS > SWITCH ON SBY
HRS
EVAC / CHARGE MODE
The unit is in Service Mode, and the refrigeration system is ready
to be evacuated then charged with refrigerant. Refer to Section
5.2.3.
EXITING PRETRIP MODE
Pretrip has been aborted either by user or by a pretrip alarm.
EXITING SERVICE MODE
Service Mode has been turned off and unit is returning to normal
operation.
FORCED LOW ENGINE SPEED
Due to current ambient conditions and power requirements, the
engine is being set to operate in Low Speed. (See Section 4.8.3,
step 1 for more information.)
FUNCTION NOT CHANGED
The = key was not pressed in the allotted amount of time to select
the new Functional Parameter setting. The new setting was not
stored and the old setting will be used.
HOUR METERS NOT CHANGED
Indicates that no changes have been made to the hour meters in
either the configuration or functional parameter lists.
INACTIVE ALARMS IN MEMORY
There are inactive alarms in the microprocessor alarm list which
have not yet been cleared.
INSTALLED, REMOVE CARD XX
An Option PC Card has been inserted into the PC Card slot, and
the option has been installed in the microprocessor. The PC Card
may safely be removed from the slot. XX indicates the number of
option installations remaining on card.
INSTALLING OPTION, PLEASE WAIT
An Option PC Card has been inserted into the PC Card slot, and
the option is being installed in the microprocessor. DO NOT RE-
MOVE THE CARD WHILE THIS MESSAGE IS BEING DIS-
PLAYED.
INSTALL STOPPED, REINSERT CARD
An Option PC Card has been inserted into the PC Card slot, and
the install process has been stopped by the PC Card not being fully
inserted in the slot, or by being removed. Remove and reinsert PC
Card to continue.
INTELLI-SLEEP MODE
The IntelliSleep IntelliSet is active. This message alternates with
“CHANGE INTELLISET TO EXIT” at 5 second interval whether unit
is running or not
KEYPAD LOCKED-BATTERY TOO LOW
Once the battery voltage goes below 7.0 Volts for 10 seconds, all
of the keys on the keypad will be locked.
LIST END, = TO CLEAR ALARMS
The end of the Alarm list has been reached. Pressing the = key will
clear the Alarm list.
LOADING INFO
A Configuration PC Card has been inserted into the PC Card slot,
and information from the card is being loaded into the micropro-
cessor. DO NOT REMOVE THE CARD WHILE THIS MESSAGE
IS BEING DISPLAYED.
MAIN MENU
Consists of Configuration Mode, Component Test and Service
Modes.
MAX SETPOINT HAS BEEN REACHED
Maximum set point allowed by configuration settings has been
reached.
MICRO WILL RESET & RESTART NOW
The microprocessor Program software has just been changed, or a
new configuration has been programmed into the microprocessor.
The microprocessor will turn itself off then on again (similar to a
computer reboot) in order for the changes to be effective.