![Carrier VECTOR 6500 Скачать руководство пользователя страница 290](http://html1.mh-extra.com/html/carrier/vector-6500/vector-6500_operation-and-service-manual_2563864290.webp)
9
−
2
62-11389
Indication/Trouble
Possible Causes
Action/Refer-
ence Section
9.1.2 Engine Starts Then Stops
Engine stops after
several rotations
Fuel supply restricted
Check
No fuel in tank
Check
Leak in fuel system
Check
Faulty fuel control operation
Engine Manual
Plugged fuel filter
8.5.5
Plugged inlet screen to mechanical pump.
8.5.3
Plugged inlet screen to electric pump.
8.5.4
Injector nozzle(s) defective
Engine Manual
Injection pump defective
Engine Manual
Air cleaner or hose restricted
8.5.9
Safety device open
2.13
ESC defective
9.5
Electric fuel pump malfunction
8.5.4
Mechanical fuel pump malfunction
Engine Manual
Oil pressure switch defective
Replace
9.1.3 Engine Will Not Shut Off
Engine will not shut off
ESC operation defective
9.5
9.1.4 Starter Motor Malfunction
Starter motor will not
crank or turns slowly
Battery insufficiently charged
9.2
Battery cable connections loose or oxidized
Check
Battery cables defective
Replace
Starter brushes shorted out
Engine Manual
Starter brushes hang up or have no contact
Engine Manual
Starter solenoid damaged
Engine Manual
Incorrect grade of lubricating oil
2.8
Starter motor turns
but pinion does not engage
Pinion or ring gear obstructed or worn
Clean both,
remove burrs,
or replace
Starter motor does not disengage
after engine starts
Starter motor solenoid defective
Engine Manual
Defective starter
Engine Manual
9.1.5 Malfunction In The Engine Starting Circuit
No power to starter solenoid (SS)
Battery defective
Check
Loose electrical connections
Tighten
ESC defective
9.5
No power to Starter Solenoid connector
9.5