MessageCenter MESSAGES - Continued
Message
Description
PRETRIP FAIL & COMPLETED
The Pretrip test is completed, and some of the Pretrip tests did not
pass. Check the Alarm List for Pretrip alarms.
PRETRIP FAIL IN TEST XX
Some of the Pretrip tests did not pass and the Pretrip was not com-
pleted. Check the Alarm List for Pretrip alarms.
PRETRIP PASS
All of the Pretrip tests were ok.
PRETRIP STOPPED BY USER
Pretrip has been stopped by user.
PRODUCTSHIELD: ECONO ON
The unit is operating in ProductShield Econo which overrides nor-
mal unit Start-Stop or Continuous Run operation. Refer to Section
4.7.3.
PRODUCTSHIELD: HIGH AIR ON
The unit is operating in ProductShield High Air which overrides nor-
mal unit speed operation. Refer to Section 4.7.3.
PRODUCTSHIELD: WINTER ON
The unit is operating in ProductShield Winter which overrides nor-
mal unit operation. Refer to Section 4.7.3.
READY TO INSTALL SOFTWARE
The microprocessor has been forced into Program Install Mode. If
this message does not clear after loading the current version of
software, check for a shorted circuit between 5MP5 and 5MP6.
RECOVER / LEAK CHK / EVAC MODE
This message will be displayed when the unit is in Service Mode
and the system is ready for recovery and leak testing.
REMOVE CARD - BATTERY TOO LOW
If a PC card is inserted when battery is below 7.0 volts this mes-
sage will be displayed until card is removed.
REMOTE SWITCH 1 (2) OPEN
Remote switch is open. May be connected to a refrigerated
compartment door or a remote control switch.
REMOTE SWITCH 1 (2) OPEN - LOW
SPEED
Shows that the remote switch is open and that the unit is running in
low speed. Switch may be connected to a refrigerated compart-
ment door or a remote control switch.
REMOVE JUMPER
The Configuration/Technician Test Mode has been entered. Re-
move the jumper wire before continuing.
SAME SW, = TO LOAD,
↑
TO CANCEL
A Program PC Card has been inserted into the PC Card slot and
the program on the PC Card is the same as the program currently
in the microprocessor. Press the = key to reload the same program
or press the UP ARROW key to cancel and remove card.
SERVICE MODE
Selection in Configuration and Technician Test Modes which is
used when servicing the refrigeration system. Refer to Section
5.2.3.
SETPOINT CHANGED
The new set point has been entered (saved into microprocessor
memory), the new set point will be used.
SETPOINT NOT CHANGED
The new set point has NOT been entered (NOT saved into micro-
processor memory), the old set point will be used.
SETTING SMV: XXX %
The Main Power Switch has been toggled out of the OFF position
and the CSMV is opening.
SLEEP MODE, OFF / ON TO WAKE
The unit is cycled off in Sleep Mode. Place the Main Power switch
in the OFF position, then back to the desired position to wake the
microprocessor up.
SLEEP WARNING: DOOR OPEN
The unit is configured for Rail Mode and the unit is in Sleep Mode
and a refrigerated compartment door is open. The unit will start as
needed for Sleep Mode.
SLEEP WARNING: NO TEMP CONTROL
The unit is running in Sleep Mode to charge the battery and (in
Engine Operation) warm the engine coolant. It is not running to
provide temperature control.
SLEEP WARNING: REMS1(2) OPEN
The unit is configured for Rail Mode and the unit is in Sleep Mode
and a remote switch is open. The switch may be connected to a
refrigerated compartment door or to a remote control switch. The
unit will start as needed for Sleep Mode.
SMV CLOSING: WAIT XXX SECONDS
Power Up and the CSMV is closing. XX indicates the number of
seconds remaining until valve is fully closed.