169
LCD Message
Description
Corrective Action
I32 New Drive x
Detected
Displays after replacing the drive when
the RAID needs to be rebuilt in Settings or
formatting is necessary.
In Settings, either rebuild the RAID array or
format the drive.
I33 Replication
Failure
An error occurred in replication, or
synchronization between the main
TeraStation and the backup TeraStation
failed during failover configuration.
In Settings, navigate to
Backup
-
Replication
and click
Resync
to execute
resynchronization. If the error is displayed
again, contact Buffalo technical support
for assistance.
I37 Recovering
System…
Settings initialization in progress.
-
I38 Recovery
Finished
Settings initialization is complete.
-
I40 All Data Will Be
Deleted
Beginning settings initialization. All data
on the drive 1 will be deleted.
-
I41 Push Func to
Start Recovery
Press the function button on the front to
start the settings initialization process.
-
I42 Preparing
Recovery
Preparing to start the settings initialization
process.
-
I43 Unsupported
Hardware
The TeraStation was started from the
USB initialization device, but the settings
cannot be initialized from this USB
initialization device.
-
I44 Drive 1 Not
Found
Initialization from the USB initialization
device was initiated, but drive 1 was not
detected.
Make sure that drive 1 is present and fully
inserted in its slot.
I45 Recovery Failed
Initialization failed.
-
I46 Migrating RAID
Array x...
Data migration or conversion (RAID
migration) is in progress.
Do not turn off the TeraStation's power.
I47 Don't Power Off
System!
I48 Push Func to
Start Failover
This TeraStation is ready to become the
failover backup for the main TeraStation.
Hold down the function button on the
front of the target TeraStation until it stops
beeping to accept failover backup status.
I49 Lost Failover
Main
The main TeraStation in the failover
configuration cannot be found.
Make sure that the main TeraStation is on,
working, and connected to the network.
I50 Failover in
Maintenance Mode
Failover maintenance is in progress.
Do not turn off the TeraStation's power.
I51 Initializing
Failover…
Initializing the failover configuration.
Do not turn off the TeraStation's power.
I52 New Firmware
Available
A new firmware version has been released.
Update the firmware.
I54 Backup Job x
Failed
The backup job failed.
Make sure that the backup job is
configured correctly. Make sure that the
NAS is on and not in standby mode. If the
backup job still fails, check the status of
NAS, network, and backup source and
destinations.
I55 Recovery Not
Authorized
Authentication during initialization of
settings failed.
Settings can only be restored for the
TeraStation whose settings were originally
saved.
Содержание TeraStation 5010
Страница 8: ...7 For Customers in Taiwan 175 ...
Страница 67: ...66 1 In Settings click Backup 2 Click to the right of Backup 3 Click List of LinkStations and TeraStations ...
Страница 75: ...74 3 Click Edit 4 Click Add 5 Click Browse under Replication Source ...
Страница 87: ...86 18Click Time Machine ...
Страница 88: ...87 19Click Select Backup Disk 20Select the TeraStation then click Use Disk ...
Страница 97: ...96 3 Click Create New Job 4 Select backup settings such as date and time to run 5 Click Add ...
Страница 103: ...102 4 Click the Options tab 5 Click Edit ...
Страница 114: ...113 7 Move the NFS switch to the position to enable NFS 8 Click to the right of NFS 9 Click the Client Settings tab ...
Страница 128: ...127 Updating Automatically 1 In Settings click Management 2 Click to the right of Update 3 Click Edit ...
Страница 137: ...136 3 Click Edit ...
Страница 138: ...137 4 Select or enter the desired MTU size and click OK ...
Страница 140: ...139 3 Click Edit 4 Clear the DHCP checkbox and enter the desired IP address and its subnet mask ...