150
Using a Redundant RAID Mode Other Than RAID 0 and TeraStation
Is Off
1
Open the front cover with the key.
2
The failed drive's status LED will be glowing red. Push its unlock button and swing the lock mechanism out.
3
Pull out the drive cartridge and remove it from the TeraStation.
4
Insert the new drive into the empty slot. Slide the drive in with the locking mechanism open. Swing the lock
back down until it clicks into place.
5
Close the front cover.
6
Press the power button on the TeraStation.
7
When the replacement drive is recognized, the status LED will flash red and the I31 information message will
be displayed on the LCD panel.
8
Press the function button on the front of the TeraStation. The TeraStation will beep. If replacing multiple
malfunctioning drives at once, select the replaced drives on Settings and click
Recover RAID Array
.
9
The TeraStation will start rebuilding the RAID array automatically. It will take about 5 minutes before the I18
message is displayed.
Using RAID 0
Drives in a RAID 0 array do not automatically turn off in the event of a malfunction. Before replacing the failed drive,
shut down the TeraStation.
This section describes the process of replacing a drive with
the TeraStation off
.
Note:
If a drive malfunctions in RAID 0, all data on the RAID array will be lost. All of the settings for the shared
folders (such as access restrictions) are erased after replacing a drive from a RAID 0 array.
1
Open the front cover with the included key.
2
The failed drive's status LED will be blinking red. Push its unlock button and swing the lock mechanism out.
3
Pull out the drive cartridge and remove it from the TeraStation.
4
Insert the new drive (sold separately) into the empty slot. Slide the drive in with the locking mechanism open.
Swing the lock back down until it clicks into place.
5
Close the front cover.
6
When the replacement drive is recognized, the status LED will flash red and the I32 information message will
be displayed on the LCD panel.
Select the RAID array from
Storage
-
RAID
in Settings and click
Delete RAID Array
. In
Storage
-
Drives
, click
Format
Drive
to format the new drive. In
Storage
-
RAID
, choose the type of RAID array desired. Enter the confirmation
number and click
OK
. Create a shared folder before use.
Содержание TeraStation 5010
Страница 8: ...7 For Customers in Taiwan 175 ...
Страница 67: ...66 1 In Settings click Backup 2 Click to the right of Backup 3 Click List of LinkStations and TeraStations ...
Страница 75: ...74 3 Click Edit 4 Click Add 5 Click Browse under Replication Source ...
Страница 87: ...86 18Click Time Machine ...
Страница 88: ...87 19Click Select Backup Disk 20Select the TeraStation then click Use Disk ...
Страница 97: ...96 3 Click Create New Job 4 Select backup settings such as date and time to run 5 Click Add ...
Страница 103: ...102 4 Click the Options tab 5 Click Edit ...
Страница 114: ...113 7 Move the NFS switch to the position to enable NFS 8 Click to the right of NFS 9 Click the Client Settings tab ...
Страница 128: ...127 Updating Automatically 1 In Settings click Management 2 Click to the right of Update 3 Click Edit ...
Страница 137: ...136 3 Click Edit ...
Страница 138: ...137 4 Select or enter the desired MTU size and click OK ...
Страница 140: ...139 3 Click Edit 4 Clear the DHCP checkbox and enter the desired IP address and its subnet mask ...