NOTE: In order to connect to the ROM reader/writer (PRW-1), the baud rate and COM port must be
correctly set in
Option Setting
on the
Tools
drop-down menu.
1. Click
Read From ROM
on the
File
drop-down menu, or the Read From ROM icon
in
the toolbar.
The Read From ROM dialog box appears.
2. Insert a sewing machine ROM into the ROM reader/writer, and Click the
Read
button.
All data in the sewing machine ROM is read and displayed in the Read from ROM dialog box.
3.
In the
Read From ROM
dialog box, make settings for the ROM file to which you want
to store the data you created.
(Refer to “
3-1-8. Reading data from a sewing machine ROM
” of “
Chapter 3.
Reference
” for details.)
4. In the
Save To ROM File
dialog box, make the following settings.
Specify the desired folder where you will store the ROM file with the
Browse
button
at the right of the
Folder Name
box.
Input the desired file name for the ROM file in the
ROM File
input box.
5. Click the
Save
button.
The ROM file is stored in the specified folder.