120/132 Demounting and replacement
Bosch Rexroth AG
, SYEPS series 1X, RE 30201-B/07.2014
11.5.7.1 Valve amplifier
NOTICE!
Voltage!
Destruction of the amplifier!
▶
Do not plug or unplug the amplifier when connected to the power supply.
After having replaced the amplifier, check and correct the valve zero point, see Chapter
8.1.14 “Adjusting 8.1.14 “Adjusting the zero point of the high-response valve” on page
73.
11.5.7.2 Pressure relief valve DBDS
When installing the valve, observe the correct tightening torque, which can be found
in the installation drawing, and make sure that the seal is properly installed.
11.5.7.3 Accumulator discharge valve KSDER
When installing the valve, observe the correct tightening torque, which can be found
in the installation drawing, and make sure that the seal is properly installed.
11.5.7.4 Pressure sensor HM20
When installing the valve, observe the correct tightening torque, which can be found
in the installation drawing, and make sure that the seal is properly installed.