Installation 51/132
RE 30201-B/07.2014, SYEPS series 1X,
Bosch Rexroth AG
Cable shield fixed to strain relief of
connector housing
Valve command value reference
Valve command value
HP command value
Position PTE reached
Position POP reached
Position PUP reached
Ready
Recommended cable type
LiYCY 5 x 0.5 mm
2
Command v
alue ±10 V
Command v
alue r
ef. 0 V
+UB 24 V supply
Valve connection
Control zero
Inputs
Enable
+10 V/max 40 V
Error
+24 VDC/max 100 mA
Outputs
CNC
PLC
M+ solenoid
M- solenoid
Control zero (GND 0 V)
Power zero (GND 0 V)
4700 μF/63 V
>100 % residual ripple U
B
Fig. 25: Wiring of the high-response valve on variant “Advanced“
For Advanced and Standard Mating connector with central screw: The screw must
be secured by means of Loctite - NOT required with High variant.
Use a standard Z4 connector for connecting the high-response valve (see data
sheet 08006).
Standard