Element name
Data type
Direction
Parameter in MLD master Parameter in axis
Significance
Configurable command value bits
wUserCmdDataBitA_q
WORD
Cmd value
P-0-172x.12
(configurable)
Command value bit for
free use
wUserCmdDataBitB_q
WORD
Cmd value
P-0-172x.13
(configurable)
Command value bit for
free use
wUserCmdDataBitC_q
WORD
Cmd value
P-0-172x.14
(configurable)
Command value bit for
free use
wUserCmdDataBitD_q
WORD
Cmd value
P-0-172x.15
(configurable)
Command value bit for
free use
Configurable command values
dwUserCmdDataA_q
SM_TYPES Cmd value
32-bit target parameter:
P-0-173x
16-bit target parameter:
P-0-182x
(configurable)
Command value for free
use
dwUserCmdDataB_q
SM_TYPES Cmd value
32-bit target parameter:
P-0-174x
16-bit target parameter:
P-0-183x
(configurable)
Command value for free
use
dwUserCmdDataC_q
SM_TYPES Cmd value
32-bit target parameter:
P-0-175x
16-bit target parameter:
P-0-184x
(configurable)
Command value for free
use
dwUserCmdDataD_q
SM_TYPES Cmd value
32-bit target parameter:
P-0-176x
16-bit target parameter:
P-0-185x
(configurable)
Command value for free
use
Configurable actual value bits
wUserActualDataBitA_i
WORD
Act. value
P-0-171x.12
(configurable)
Actual value bit for free
use
wUserActualDataBitB_i
WORD
Act. value
P-0-171x.13
(configurable)
Actual value bit for free
use
wUserActualDataBitC_i
WORD
Act. value
P-0-171x.14
(configurable)
Actual value bit for free
use
wUserActualDataBitD_i
WORD
Act. value
P-0-171x.15
(configurable)
Actual value bit for free
use
Configurable actual values
dwUserActualDataA_i
SM_TYPES Act. value
32-bit source parameter:
P-0-177x
16-bit source parameter:
P-0-186x
(configurable)
Actual value for free use
dwUserActualDataB_i
SM_TYPES Act. value
32-bit source parameter:
P-0-178x
16-bit source parameter:
P-0-187x
(configurable)
Actual value for free use
dwUserActualDataC_i
SM_TYPES Act. value
32-bit source parameter:
P-0-179x
16-bit source parameter:
P-0-188x
(configurable)
Actual value for free use
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
Bosch Rexroth AG
93/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
MLD communication interfaces and data channels
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01