In the drive, the system files:
–
... are distributed to list parameters P-0-1352 to P-0-1358 and stor‐
ed.
–
... are stored on the external memory card as a file, which requires
that a memory card be used and the corresponding "MLD configu‐
ration" be made in IndraWorks or P-0-1367 be parameterized.
●
The boot project first does not have any influence on the program cur‐
rently running in the RAM. Only after the drive has been switched on
again is the boot project loaded to the RAM and possibly started.
●
As an alternative, changed boot projects are loaded when the drive
switches to operating mode (P3 to P4).
File system in the drive
The table below shows all files available in the drive. Many of the files are not
directly visible to the user or are automatically managed. All "system file" type
files are directly managed by the drive firmware. The PLC system files are
managed by IndraLogic.
This means that there are files which are used internally and only exist in the
memory. Furthermore, there are files available in the form of parameters, in‐
dependent of the external memory card. All other files are contained on the
memory card.
In the "Documentation" directory, the user can store their own files for docu‐
menting their system/machine.
Medium
Directory
File
Type
Contents
Access
Parameter P-0-1352 -
Application.sts
PLC system file
PLC status
Logic context menu: Start/
Stop
-
Application.crc
PLC system file
(P-0-1367.0.8=0)
Boot
application
checksum
Logic context menu: Cre‐
ate boot project
Parameters
P-0-1353
to
P-0-1358
(IndraDrive only)
-
Application.app
PLC system file
(P-0-1367.0.8=0)
Boot application
Internal flash
(HydraulicDrive on‐
ly)
-
Application.app
PLC system file
(P-0-1367.0.8=0)
Boot application
External
memory
card
Plc
Application.crc
PLC system file
(P-0-1367.0.8=1)
Boot
application
checksum
Application.app
PLC system file
(P-0-1367.0.8=1)
Boot application
Archive.prj
PLC system file
Source code archive Logic context menu: Load
source code
Documentation
*.*
User files
Installation
docu‐
mentation
External
Tools
*.*
User files
Tools
External
User
*.*
User files
User files
PLC program with "Sys‐
File", FTP or IndraWorks
Explorer
Backup
*.*
PLC system file
Retain data and pa‐
rameter backup
Logic: "Backup" com‐
mand
Tab. 7-1:
File system in the drive
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
Bosch Rexroth AG
185/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Notes on commissioning and application