Fig. 7-3:
Communication with the programming interface
Ethernet interface (TCP/IP)
At the drive, the Ethernet Engineering Port (HCS01) is used. An Ethernet in‐
terface with TCP/IP protocol is required for communication. The settings of
the TCP/IP communication can be made in IndraWorks via the context menu
of the drive (pertinent parameters: P-0-1531, P-0-1532 and P-0-1533).
MLD settings in IndraWorks
Requirements
The drive should have been fully commissioned before programming MLD.
Settings
The settings for the "IndraMotion MLD" function can be configured under the
"MLD" branch. The screenshot below shows the options provided in the
IndraWorks Project Explorer:
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
Bosch Rexroth AG
171/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Notes on commissioning and application