Amount of resources (memory)
"IndraMotion MLD" has the following resources:
●
Internal code memory (RAM in control section):
About 33% of the memory resource indicated here are reserved
for the "Online Change" function, i.e., about 66% are available.
–
Basic: 2 MB (non-storing)
–
Advanced: 12 MB (non-storing)
●
Program size (boot program):
–
About 650 kB with Basic control panel and Advanced control panel
in parameter memory
–
About 8 MB with Advanced control panel and MicroSD memory
card (optional memory card has to be enabled via P-0-1367)
The boot project is loaded to the code memory (RAM) from the
program parameters when the device is switched on. This is why
the program memory must be big enough to store the project.
●
Data memory:
About 10% of the memory resource indicated here are reserved
for the "Online Change" function, i.e., about 90% are available.
MPB: 3 MB
MPC: 9 MB
There are several data areas with different uses (instances are varia‐
bles):
–
Global: Memory for global variables
2048 kB
Note: The instance data are mapped via global variables. All func‐
tion data are not stored in this segment but in the stack.
–
Memory: All flag variables addressed with "%M"
32 kB
–
Input: All input variables addressed with "%I"
16 kB
–
Output: All output variables addressed with "%O"
16 kB
–
Retain
variables
and
persistent
variables
(
VAR_GOBAL PERSISTENT RETAIN
):
–
472 bytes on Basic control panel (MPB18VRS)
–
31704 bytes on Advanced control panel (MPC18VRS) in
FRAM