to switch CCD communication to phase 2 in order to write parame‐
ters in the CCD group.
Fig. 4-3:
Overview of MLD‑M device control and axis commanding
MLD function block and system-wide variable for axis control
Function block:
●
"MX_SetDeviceMode": Firmware function block for axis control, uses
S-0-0420, S-0-0422, S-0-0424
System-wide variable:
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
Bosch Rexroth AG
45/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Basic functions of Rexroth IndraMotion MLD