Fig. 7-16:
Check the PLC Compiler Version
2. Execute Build ▶ Clean all.
3. Execute Build ▶ Generate code.
4. Execute Debug ▶ Login.
5. Execute Debug ▶ Start.
6. When the boot application is not implicitly generated in the properties of
the application during the download, this must be done via De‐
bug ▶ Create boot application.
7. Execute Debug ▶ Logout.
Archiving the MLD Project
After the MLD project has been prepared for archiving, it can be archived.
The project can be archived in online and offline mode.
In offline mode, the MLD project is archived with the offline data.
Before archiving starts, the "Archiving of Drive Parameters" dialog
provides the possibility of updating the offline data.
The following steps must be carried out for archiving the IndraWorks MLD
project:
1. Start IndraWorks MLD.
2. Select Project ▶ Archive….
3. Define archive name and comment for the archive.