Loading the source code
After login, IndraLogic allows all PLC project information to be packed in a file
with Online ▶ Load source code. If an external memory card has been plug‐
ged in the drive, this file (packed source code) can be written to the memory
card.
It is recommended that you do not use this function.
Opening a project in the control unit
In IndraLogic, the dialog opened via File ▶ Open contains the "PLC…" button.
When the connection to a drive controller has been established and you click
this button, a project is opened in the control unit after a target has been se‐
lected and the communication parameters have been set.
It is recommended that you do not use this function.
Archiving an MLD Project
Objective
To commission an MLD project in an identical installation, you can archive
the project. The archived project contains all data and settings so that you
can log in (establish an online connection) to a running installation without
having to re-compile the MLD project.
It is recommended to generate a package with all required com‐
ponents (e.g. in the form of a CD or DVD) to make any PC, which
meets the system requirements, a programming system for
IndraMotion MLD. The package should contain the following com‐
ponents:
●
The same or higher version of IndraWorks MLD as used
when the archive was created.
●
The archive (.zip) of the MLD project.
Preparing the MLD Project for Archiving
To make sure that you can log in to the running MLD project without repeated
compilation after the archived project has been restored, you have to carry
out the following steps in IndraWorks before archiving the project:
1. Call Project ▶ PLC Compiler Version… and make sure that the latest
PLC compiler version has been selected.
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
Bosch Rexroth AG
191/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Notes on commissioning and application
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01