Fig. 6-16:
"Fix Settings"
Step 4: Calling "IP Address"
The configuration dialog for setting a fixed IP address is called via "IP Ad‐
dress". After the password (step 5) "+-+-" has been entered, the IP address
and the subnet mask can be entered.
Fig. 6-17:
Entering IP address and subnet mask
Step 6: Entering IP address and
subnet mask
1.
Enter the IP address and the subnet mask.
2.
Confirm your input with "Ok".
Menu "Fix Settings" appears again. Clicking "home" in "Fix Settings"
and "home" in "IP Settings" moves the system back to the main menu of
"Setup-Main".
Step 7: "Save Registry To flash"
In the menu "Setup-Main", press "Exit". The query "Save Registry To flash" is
displayed.
The settings will only be saved after you have confirmed the
query "Save Registry To flash" with "OK"!
Reading drive parameters
The following sections describe the steps required to read drive parameters
with the "IndraControl VCP" operator terminal.
Please make sure that all configurations and settings have been
made at the "IndraControl VCP" operator terminal.
1. In the project folder, right-click on folder "Screens" and select "New
screen". Create a new screen with name "Read drive 2".
The new screen is displayed in the right upper window.
Bosch Rexroth AG
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
150/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Visualization and engineering interfaces