"MC_MoveAbsolute"/"MX_MoveAbsolute",
"MC_MoveRela‐
tive"/"MX_MoveRelative", "MC_MoveAdditive"/"MX_MoveAdditive": "Po‐
sitioning" operation mode
●
"MC_Jog": "Positioning (jog +/-)" operation mode
●
"MC_GearIn", "MC_GearOut": "Velocity synchronization " operation
mode
●
"MB_GearInPos", "MC_CamIn", "MC_CamOut": "Position synchroniza‐
tion" operation mode
●
"MB_Phasing", "MB_PhasingSlave": Additive position offset for position
synchronization
●
"MB_MotionProfile": "Position synchronization" operation mode with mo‐
tion profiles
Parameters and diagnostic messages for commanding axes
●
"P-0-1367, PLC configuration", bit 4: Activates "permanent control" of
the local axis for MLD
●
"P-0-1800.0.1, CCD: Configuration", bits 4 and 3: Activates MLD-M sys‐
tem mode
●
Parameters of used "velocity control", "torque control", "position syn‐
chronization", "drive-controlled positioning" and "velocity synchroniza‐
tion" operation modes
●
Parameters of the "internal operation modes" with temporary control for
the operating mode as intelligent servo axis:
–
P-0-1450, PLC/setting-up mode Positioning command value
–
P-0-1451, PLC/setting-up mode, positioning velocity
–
P-0-1452, PLC/setting-up mode, positioning acceleration
–
P-0-1453, PLC/setting-up mode, positioning deceleration
–
P-0-1454, PLC/setting-up mode, positioning command value ac‐
ceptance
–
P-0-1455, PLC/setting-up mode, positioning command value ac‐
knowledge
–
P-0-1460, PLC/setting-up mode, velocity command value
–
P-0-1461, PLC/setting-up mode Ramp pitch
–
P-0-1463, PLC/setting-up mode Deceleration ramp
–
P-0-1465, PLC/setting-up mode Torque/force command value
Working with retain variables
Retain variables are designated by the keyword "RETAIN". These variables
keep their value after uncontrolled termination and after the control unit is
switched off and back on normally (according to the "Online" "Reset" com‐
mand). When the program is restarted, work continues with the stored val‐
ues. One application example is a piece counter in a production line which is
expected to continue to count after a power failure. All other variables are re‐
initialized in this case, either with their initialized values or with the standard
initializations. Retain variables are reinitialized after "reset cold", "reset origi‐
nal" and - in contrast to persistent variables - after the program is downloa‐
ded again.
Depending on the hardware (standard or Advanced control panel with memo‐
ry card), either 472 bytes or 31704 bytes are available for retain variables
and persistent variables.