Setting Run-time Parameters
893-743-A
4-39
Enter the IPX node address of the trap receiver you are adding.
It must be 12 hexadecimal characters. When you press [Enter], the
screen displays the message:
Enter new trap receiver’s community string:
Enter the community string of the new trap receiver. When you
press [Enter], the screen displays the message:
Enter new trap receiver’s age-out time
(in units of 10 msec):
Enter the age-out time of the new trap receiver. The screen scrolls
and adds a new entry to the displayed list of defined trap receivers.
d
[Delete a receiver] When you issue this command, the screen
displays the message:
Enter the number of the entry to delete:
Enter the number (1 through 10) of the entry you are deleting. The
screen scrolls and changes the deleted entry to read [none] on the
displayed list of defined trap receivers.
ESC
[Return to SNMP Parameters Menu] Returns the display to the
SNMP Parameters menu.
NOTE:
The age-out time specifies the length of time in milli-
seconds an entry may stay in the trap receiver’s table. Once an
entry ages out, it is removed from the table. When a management
station learns about a Model 281xSA hub on the network, it auto-
matically registers its IPX address in the trap receivers table and
sets the age-out timer to 180,000 milliseconds (30 minutes). Every
10 minutes it reregisters. If a management station is removed from
the network or does not reregister, the Model 281xSA hub ages out
the IPX address. When the timer is set to 0 milliseconds, the entry
never ages out.