Sample Configuration File
893-743-A
G-7
# OB = object, which is one of the following:
# conc Threshold is set for a concentrator
# slot Threshold is set for a slot
# port Threshold is set for a port
# SL = slot number, for 281xSA concentrator from 1 to 5, inclusive
# PO = port number, from 1 to 17, inclusive
# TY = type, which is one of the following:
# good-bytes
# good-packets
# bad-packets
# crc-error-packets
# misaligned-packets
# runt-packets
# fragments
# too-long-packets
# collisions
# late-collisions
# link-status
# multicast-packets
# broadcast-packets
# short-events
# source-address-changes
# data-rate-mismatches
# network-errors
# backoff-errors
# bad-to-good-packets-ratio
# network-errors-to-good-packets-ratio
# collisions-to-good-packets-ratio
# CN = condition, which is one of the following, depending on TY:
# cross Trigger alarm when actual-value crosses set-value
# over Trigger alarm when actual-value is greater than set
# value
# over-rate Trigger alarm when actual-value/second is greater
# than set-value/second
# link-on Trigger alarm when port link status is on
# link-off Trigger alarm when port link status is off
# over-rate Actual-value/second is greater than set-value/second
# over-ratio Actual-value (ratio type only) is greater than set
# value
# SV = set value, which can be an absolute number or a rate per second
# AC = action, which is one of the following:
# trap-only Send trap only
# partition-slot Partition a slot, specified by SL
# partition-port Partition a port, specified by SL and PO
# trap-partition-slot Send trap and partition a slot, specified by
# SL
# trap-partition-port Send trap and partition a port, specified by
# SL and PO