Network Configurations and Cable Connections
3-10
893-743-A
5.
Connect the other end to a 10BASE-T port on the Model 281xSA hub
(see Figure 3-9).
Figure 3-9. Model 281xSA hub 10BASE-T port connection
6.
Verify that the port Link LED is ON.
Repeat steps 1 through 6 until all Ethernet stations are connected to 10BASE-T
ports on the Model 281xSA hub.
See Appendix C, “Pin Assignments,” for the pin assignments of the RJ-45
connector on the Model 281xSA hub.
The System 2000 hubs support automatic polarity detection and correction,
which detects and automatically corrects for signal inversions on the UTP
receive data wire-pair. If any receive data wire-pair was mistakenly reversed in
the punchdown block during cable installation, the System 2000 hub internally
corrects for the miswiring, and the data path operates correctly. For more
information about this feature, see Appendix E, “Autopolarity Detection and
Correction.”
NOTE:
The System 2000 Ethernet hubs support the 10BASE-T specified link
integrity test function. See Appendix D, “Link Integrity Test Function,” for a
complete description of this feature.
UTP
cable