Setting Run-time Parameters
893-743-A
4-37
Enter the community string of the new trap receiver. When you
press [Enter], the screen displays the message:
Enter new trap receiver’s age-out time
(in unit of 10 msec):
Enter the age-out time of the new trap receiver. The screen scrolls
and adds a new entry to the displayed list of defined trap receivers.
d
[Delete a receiver] When you issue this command, the screen
displays the message:
Enter the number of the entry to delete:
Enter the number (1 through 10) of the entry you are deleting.
The screen scrolls and changes the deleted entry to read [none]
on the displayed list of defined trap receivers.
ESC
[Return to SNMP Parameters Menu] Returns the display to the
SNMP Parameters menu.
SNMP Trap Receivers for IPX
When you select the x command [Set IPX trap receivers] from the SNMP
Parameters menu, the menu shown in Figure 4-22 is displayed.
NOTE:
The age-out time specifies the length of time in milli-
seconds an entry may stay in the trap receiver’s table. Once an
entry ages out, it is removed from the table. When a management
station learns about a Model 281xSA hub on the network, it
automatically registers its IP address in the trap receivers table
and sets the age-out timer to 180,000 milliseconds (30 minutes).
Every 10 minutes it reregisters. If a management station is
removed from the network or does not reregister, the Model
281xSA hub ages out the IP address. When the timer is set to 0
milliseconds, the entry never ages out.