Installing the Model 281xSA Hub
2-2
893-743-A
Operating Environment Requirements
Make sure the area where you intend to install the Model 281xSA hub provides
the following environmental conditions:
■
Temperature
–
Ambient temperature between 5
°
and 40
°
C (41
°
and 104
°
F)
–
No nearby heat sources such as direct sunlight, warm air exhausts, or
heaters
■
Humidity
–
Between 5% and 85% noncondensing
■
Ventilation
–
Minimum 2 inches on all sides for cooling
–
Adequate airflow in room or wiring closet
■
Operating conditions
–
At least 6 feet to nearest source of electromagnetic noise (such as
photocopy machine or arc welder)
–
No dust
Physical Location Requirements
There are certain physical requirements for installing the Model 281xSA hub,
whether you are installing the hub on a table, in a rack, or on a wall. Make sure
your location meets the following requirements:
■
Service access
–
Minimum 12 inches front and rear for service access and maintenance
–
Front and rear clearance for cables and wiring hardware such as
punchdown blocks
■
Power
–
Adequate power source within 6 feet
■
Table installation requirements
–
Approximately 10-inch by 18-inch area on a level tabletop or shelf
–
Support for at least 10 pounds