893-743-A
B-3
Table B-2 describes the meanings of combinations of the
µ
P Fault and On Line
LEDs.
Host Port
LEDs
(16 pairs)
Part
Amber
Port has been autopartitioned because of an
excessive number of consecutive collisions or
an excessively long single collision signal; or
it has been partitioned by SNMP network
management or local hub management.
Link
Green
Port is connected to another powered
10BASE-T port whose signaling meets the
requirements for an IEEE 802.3i 10BASE-T
device. This LED turns OFF if a port has been
partitioned by network management.
Operation
LEDs
On Line
Green
Flashes when the Model 281xSA hub has not
yet started to execute the run-time image
software code. This LED lights to indicate that
the download (or local load) has succeeded and
has begun to execute the run-time image. If the
µ
P Fault LED is on, the On Line LED lights to
indicate that the concentrator is running its self-
test or that the download has failed eight times.
NM Cntrl
Amber
Lights when the concentrator has been isolated
(partitioned) from the cluster “backplane” or
when one or more ports have been partitioned
by SNMP network management.
µ
P Fault
Amber
Lights when a microprocessor fault has
occurred in the concentrator. This LED lights
during power-on self-test and reset, then turns
off if the tests are successful.
Table B-2. Model 281xSA hub
µ
P Fault and On Line LED
combinations
µ
P Fault On Line
µ
P Fault
ON
OFF
Running self tests, or download failed after eight
attempts.
OFF
Flashing
Waiting for download, or download in progress.
OFF
ON
In operation.
Table B-1. Model 281xSA hub LEDs (continued)
Type
Label
Color
Meaning