No
Write 0 to Device
Control Command Word
Start
Write desired program number (as a
32-bit integer) into the Product
Change Number location
Make sure Camera is Ready – bit 0
is set to 1 in Inspection Status Word
Execute Product Change: set bit 0 of
the Device Command Word to 1
Product change successful
Is Product Change ACK
(bit 0 in Device Control
ACK Word) set to 1?
Yes
No
Read error code. Correct
the error condition
Yes
Done
Is Execution Error (Device
Control ACK Word bit 15) set
to 1?
Figure 342. Product Change—PROFINET
Verify :
Ready = 1
ProductChange
ACK = 0
Ready
Product
Change
ProductChange
ACK = ‘1’
New inspection
is loaded
RPI 0
1
X
X+Y
X+Y+Z
Product
Change
ACK
Set
ProductChange
= 1
Verify :
Ready = 1
ProductChange
ACK = 0
Set
ProductChange
= 0
Product Change
X, Y, Z: Represent snapshots in
time
Figure 343. Product Change Timing Diagram
Sensor Output Submodules
The Sensor Output Submodules contain
user-defined
maps of sensor output data. There are six versions with 16, 32, 64, 128, 256, and
512 bytes, depending on the size of the output data. A sensor output submodule can be added to slot 2, subslot 1.
Table 32: Sensor Output Submodule
Submodule
PLC Input Data
PLC Output Data
Name
Ident No.
Name
Type
Name
Type
16-Byte Custom Map
0×000028
User-mapped Sensor Result Data Block
16-byte OctetString
Not applicable
Not applicable
VE Series Smart Camera