13.6.5
Description
of Submodules
VE
Inspection
Results Submodule
The VE
Inspection
Result submodule contains
inspection
results and sends input data into the controller (PLC). This submodule is
plugged into Slot 1 Subslot 1 and cannot be removed.
Table 30: VE
Inspection
Result Submodule (Ident 0x000101)
PLC Input Data Name
Input Data Type
Inspection
Status Word
Unsigned16
Inspection
Number
Unsigned32
Sensor Pass/Fail Bits
Unsigned32
Iteration
Count
Unsigned32
Pass Count
Unsigned32
Fail Count
Unsigned32
Missed Trigger Count
Unsigned32
Current
Inspection
Time
Unsigned32
Inspection
Status Word
Bit
Position
for Cyclic Input Data
Function
Bit 0
System Ready
Bit 1
Inspection
Pass/Fail
Bit 3
Ready Signal Latch
Bit 5
Output 1 ON/OFF
Bit 6
Output 2 ON/OFF
Bit 7
Output 3 ON/OFF
Bit 8
Output 4 ON/OFF
Bit 9
Output 5 ON/OFF
PLC Output Data Name
Output Data Type
Not applicable
Not applicable
Sensor Pass/Fail Bits
Bit
Position
Function
Bit 0
Camera Tool Pass/Fail
Bit 1
Vision Tool 1 Pass/Fail
...
...
Bit 32
Vision Tool 31 Pass/Fail
VE Series Smart Camera