Страница 7: ...NOTE Parts with marked are not Available...

Страница 8: ......

Страница 9: ...PARTS NO _DESCRIPTIOtl 6617202U E Rine...

Страница 10: ...S 66001037 and take off the W lever 147651 and the lever mount 147652 Cautions The W lever SS is of the left handed screw 3 Remove the top cover nut 147659 Begin removal of the shutter dial Set the sh...

Страница 11: ...e top cover by the right hand and remove it by lightly rolling 9 Disconnect the soldered synchro lead wires black and light brown inside the top cover Removal of Front Leather 1 Peel off the self leve...

Страница 12: ...d remove it Removal of Counter Frame 1 Remove counter reverse lever spring 147870 engaging with the counter gear 1 139887 2 Remove 3 counter base plate SS 61913024 and take it out upward to remove Rem...

Страница 13: ...rive cam and then it stops Operation of Shutter 1 The release lever is pushed down by MCL 7 of the mirror box and the hook is separated from the drive cam 2 The drive cam rotates clockwise due to the...

Страница 14: ...same as the ordinary ones Faults that may occur The shutter fails to close Because of the flatness of B lever being dis Bulb skipping satisfactory it does not return Change the release position by SR...

Страница 15: ...per half darkens and the shutter speed becomes fast The front curtain travel is slow Cause The shutter moquette 147206 enters the inside of the shutter and contacts with the front curtain when the lat...

Страница 16: ......

Страница 17: ...he result of which is as V2 sent to A2 Vreg A constant voltage of 1 25 0 15V is generated independent of variation of a voltage Vcc from the battery Ra2 Adjust the voltage per EV of Rp and Rasa The a...

Страница 18: ...counter release lever and next put the spring in the counter release lever shaft Counter making a little free the wound portion at the central part of the spring then apply the hook on the opposite s...

Страница 19: ...hort circuits of RF Rasa Ral etc including failure in SPD 4 One or 2 of 3 LED s go on and off but the remainder do not go on 1 Disconnection of soldered legs of LED 2 Disconnection of R5 through R7 3...

Страница 20: ...t of the winding lever 2 Regarding paragraphs 2 and 3 check the shaft or base for dimensions and replace one of them which is not acceptable Note Check the counter for advance return etc Faults that m...

Страница 21: ...ever shaft from above to 1 create a play 0 Loosen 3 screws of the winding shaft holder and again tighten the 3 screws at the position __ where the winding shaft rotates smoothly Faults that may occur...

Страница 22: ...mes insufficient Reparing technique and confirming method The clearance between GS ring and QRL 4 should be within 0 1 mm to 0 3 mm and GS ring installed in parallel with QRL 4 Phenomenon Concurrently...

Страница 23: ...slit shape at the upper side Cause The sticking position of the shutter moquette 1 is not appropriate so that the two side adhesive tape of the shutter moquette 1 sticks to the rear curtain stop leve...

Страница 24: ...ses them to have an aptitude to slipping Repairing technique and confirming method Bend SR lever 3 from the side touching QRL 1 by use of a screw driver of No 5 or so to such an extent that SR lever 3...

Страница 25: ...scend that is there occur conditions that the film cannot be wound and the shutter released Cause If something should touch the rear curtain of the shutter or catch it when it runs it cannot run all t...

Страница 26: ...the mirror is felt or the mirror fails to descend being left up Cause When crimping ML 1 to M frame the former is deformed and its top with a groove parts outward from M frame with the result that it...

Страница 27: ...the washer Faults that may occur The mirror does not operate smoothly The mirror is not reset Phenomenon When moving the mirror upward by hand and gently returning it the mirror does not return all th...

Страница 28: ...ing technique and confirming method In order to stop a play of MCL 3 GS ring should be stopped such that it is parallel with MC base and the play should be stopped to such an extent as MCL 3 moves aut...

Страница 29: ...of lot Example ICB BCB Interchangeability of parts Counter base ass y is replaceable but singles such as Counter Counter clamp 147871 Counter gear 147865 are not interchangeable Counter SP 147867 Cou...