Inspection
Pass/Fail
Select the Contribute to
Inspection
Pass/Fail check box (default) if the tool will
influence
the Pass/Fail status of the
inspection.
Figure 268.
Inspection
Pass/Fail
The Pass/Fail
contribution
influences
the following:
• Discrete output Pass
• Discrete output Fail
• Pass/Fail results counter
• Pass (Green) and Fail (red) LEDs on the Sensor
Select this checkbox if the overall Pass/Fail status of the
inspection
is dependent on the current tool.
9.2.3 Measure Tool: Test Parameters
Use the Test parameters to
configure
the pass/fail
conditions
for the tool.
Select the parameter checkbox to enable it. Where applicable, the
vertical
green bar shows the current parameter
information
and the
light gray backgrounds show the range over which a value has varied over
time.
Figure 269. Measure Tool—Test Parameters
Distance
The straight-line distance between two constants or tools.
Distance X
The x dimension vector component of the straight line
distance.
Distance Y
The y dimension vector component of the straight line
distance.
Angle
The angle with respect to the x axis, along which the
straight line measurement vector lies. If the tool is
measuring from one Line tool to another Line tool, the
Angle is the measurement of the angle formed by the two
lines. If the Force to Absolute parameter is selected, the
angle is calculated
relative
to the reference tool that
precedes the Measure tool.
9.2.4 Measure Tool: Results
Tools & Results and All Results list
information
from the current and previous
inspections.
A red box around a tool indicates that the tool failed. Status provides
information
about the
specific
failure.
All Results displays the Result, Time, Pass Count, and Fail Count
information
at a glance. Expand the
inspection
tool to see
specific
results for that tool.
Distance
The straight-line distance between two constants or tools.
Distance X
The x dimension vector component of the straight line distance.
Distance Y
The y dimension vector component of the straight line distance.
Angle
The angle with respect to the x axis, along which the straight line measurement vector lies. If the tool is measuring from one
Line tool to another Line tool, the Angle is the measurement of the angle formed by the two lines. If the Force to Absolute
parameter is selected, the angle is calculated
relative
to the reference tool that precedes the Measure tool.
Mid Point
The x and y coordinates of the middle point between the two selected points.
Mid Point is calculated for point to point measurements only.
VE Series Smart Camera
www.bannerengineering.com - Tel: 763.544.3164
133