WORD #
WORD NAME
DATA TYPE
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current
Inspection
Time
Float
16
Sensor Pass/Fail Bits (see
on page 158)
16-bit integer
17-500
User-defined
(see
on page 190)
16-bit integer
13.5.4 Input and Output Bits
The Input Bits are used to command
execution
of basic
functions.
The Output Bits are used to push single bit outputs from the VE Series
camera to the PLC. The 32 bits of VE Series camera output can also be accessed using the bits of the
first
two Output Registers (Input
Bits ACK Register(word 0) and Output Bits Register (word1)).
Table 22: Input Bits Register (Command Bits)
Bit
Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
Input
String
reserved
reserved
reserved
reserved
Trigger
Teach
Latch
Product
Change
Table 23: Input Bits ACK Register (ACK Bits)
Bit
Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
reserved
reserved
reserved
reserved
reserved
reserved
reserved
Input
String ACK
reserved
reserved
reserved
reserved
Trigger
ACK
Teach
Latch ACK
Product
Change
ACK
Table 24: Output Bits Register (Sensor Status Bits)
Bit
Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Execution
Error
System
Error
Teach
Error
Missed
Trigger
reserved
reserved
Output 5
Output 4
Output 3
Output 2
Output 1
reserved
Ready
Latch
reserved
Pass/Fail
Ready
13.5.5 Sensor Pass/Fail Bits
For the sensor pass/fail bits, pass = 1 and fail = 0.
Table 25: Sensor Pass/Fail Bits
Bit
Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Vision Tool
15 Pass/
Fail
Vision Tool
14 Pass/
Fail
Vision Tool
13 Pass/
Fail
Vision Tool
12 Pass/
Fail
Vision Tool
11 Pass/
Fail
Vision Tool
10 Pass/
Fail
Vision Tool
9 Pass/Fail
Vision Tool
8 Pass/Fail
Vision Tool
7 Pass/Fail
Vision Tool
6 Pass/Fail
Vision Tool
5 Pass/Fail
Vision Tool
4 Pass/Fail
Vision Tool
3 Pass/Fail
Vision Tool
2 Pass/Fail
Vision Tool
1 Pass/Fail
Camera
Tool Pass/
Fail
13.5.6
Tool-Specific
Results: PCCC
Configure
the VE to output
user-defined,
tool-specific
results to the PLC using a custom map.
The output submodule includes both
system-defined
and
user-defined
results in the map. To set the
user-defined,
tool-specific
results
in the custom map, navigate: System
Settings
>
Communications
> Industrial Protocols.
VE Series Smart Camera
190