13 Industrial Ethernet Overview
13.1 Industrial Ethernet Setup
13.1.1 Set the Industrial Ethernet Protocol (EtherNet/IP, PROFINET
®
, Modbus/TCP, PCCC)
The Industrial Ethernet
communication
channel is disabled by default.
To enable this channel, use the following
instructions:
1. From the System
Settings
screen, click
Communications
, then click Industrial Protocols.
2. Select the desired protocol from the list.
• Disabled (default)
• EtherNet/IP
• PROFINET
®
• Modbus/TCP
• PCCC
Only one type of
connection
can be established at a
time.
3. Select the desired 32 Bit Format from the list.
32 bit Format determines how 32 bit integers and
floating
point values are stored in
sequential
16 bit registers (words)—least
significant
word
first
(LSW-MSW) or most
significant
word
first
(MSW-LSW).
Word
Value
0
LSW
1
MSW
OR
Word
Value
0
MSW
1
LSW
Note: To
configure
the
tool-specific
results, see:
•
on page 159
•
on page 180
•
on page 190
•
on page 199
13.1.2 Set the Trigger Mode
Trigger the sensor using either the hardware trigger or through the Industrial Ethernet.
To only accept triggers generated through the Industrial Ethernet
communication
channel, set the trigger to Industrial Ethernet.
Note: An Industrial Protocol must be enabled from System
Settings
>
Communications
> Industrial Protocols before
setting
the
trigger to Industrial Ethernet.
1. On the Sensor screen, click the Camera tool.
The Inputs tab displays.
2. On the Inputs tab, expand Trigger.
3. Select Industrial Ethernet from the Trigger Mode list.
13.2 Supported
Functions
The VE Series camera is controlled over an Industrial Ethernet
connection
using the input and output data it makes available over the
protocol.
The following are examples of sensor
functions
that can be performed using input and output values:
• Product change
• Remote teach
• Sensor trigger
• Read output indicators (pass/fail/ready/error)
VE Series Smart Camera
152
www.bannerengineering.com - Tel: 763.544.3164